ae Daily-Use Ceramic Thermal Stability Tester - Ceramic Testing Instrument

Xiangke RSQ05 Daily Ceramic Thermal Stability Tester - Ceramic Testing Instrument. The thermal stability tester meets GB/T3298-1991 and GB/T3298-2008 standards for the determination of thermal shock resistance of daily-use ceramics and is suitable for determining the thermal stability of daily-use ceramics.

Product Description

Xiangke RSQ05 Daily-use ceramic thermal stability tester - Ceramic testing instrument Thermal stability tester

This instrument meets the requirements of GB/T3298-1991 and GB/T3298-2008 for the determination of thermal shock resistance of daily-use ceramics. It is suitable for the determination of thermal stability of daily-use ceramics and glass products. It adopts the immersion method to test the thermal stability and thermal shock resistance of ceramic and other materials.

Xiangke RSQ05 Daily-use ceramic thermal stability tester - Ceramic testing instrument Main technical parameters:

1. Maximum operating temperature of the furnace body: 300℃;

2. Size and temperature difference of the uniform temperature zone: 300×300×300 mm, ±5℃; 
3. Temperature control accuracy: ±5℃ (at 300℃); 
4. Effective volume (material basket size): 300×300×300 mm; 
5. Cold furnace heating time: 60 minutes (from room temperature to 300℃); 
6. Cold material into the furnace temperature rise time: 5 minutes (300℃, material weight 7㎏); 
7. External dimensions: 1500×1600×850 mm (length × height × width); 
8. Water tank temperature control range: 15-50℃; 
9. Temperature control accuracy: ±2℃; 
10. Water temperature non-uniformity: ±2℃; 
11. Temperature rise within 5 minutes of hot material entering water: ±4℃ (material temperature 300℃, 7㎏); 
12. Heating furnace power consumption: 6kw; 
13. Maximum power consumption of water and electric heater: 4kw; 
14. Compressor power: 2.2kw; 
15. Timer range: 0~120 minutes.

16. Equipped with an electric lifting device, press the lifting button to transfer materials. 
Working conditions 
1. Ambient temperature: 0~40℃; 
2. Power supply: 3×220V, 10kw, 50HZ; 
3. Cooling water inlet temperature: below 35℃.

Instrument configuration: including one RSQ05 test host and one sample rack.