Papua New Guinea Fully Automatic Specific Heat Capacity Tester

Xiangtan Xiangke BRR-3 series fully automatic specific heat capacity tester, specific heat capacity meter is used for high-accuracy measurement of specific heat capacity at different temperatures, and meets the requirements of GJB 330A-2000 standard. All measurements and controls of this instrument are computer-controlled, reducing human error and improving testing accuracy.

Product Description

Xiangtan Xiangke BRR-3 series Fully automatic specific heat capacity tester Specific heat capacity measuring instrument

The BRR-3 series specific heat capacity tester is used for high-accuracy measurement of specific heat capacity at different temperatures, and meets the requirements of the GJB 330A-2000 standard for testing the specific heat capacity of solid materials. All measurements and controls of this instrument are computer-controlled, reducing human error and improving testing accuracy.

Xiangtan Xiangke BRR-3 series Fully automatic specific heat capacity tester Main technical parameters:

Instrument model specifications

BRR-3A (high temperature)

BRR-3B (medium temperature)

BRR-3C (room temperature)

BRR-3D (low temperature)

1. Specific heat capacity range

0.05-5 (kj/kg*k)

0.05-5 (kj/kg*k)

0.05-5 (kj/kg*k)

0.05-5 (kj/kg*k)

2. Testing accuracy

Solid ≤1%±0.002; Powder ≤2%±0.002

Solid ≤1%±0.002; Powder ≤2%±0.002

Solid ≤2%±0.008; Powder, liquid ≤3%±0.008

Granular, powder ≤1%±0.002

3. Test temperature range

200—1300℃ or 400—1550℃

100—800℃

Room temperature—100℃

-40—100℃

4. Sample requirements

Solid sample size, (φ10—φ14) × (20—40) mm; Powder about 6 (cm3)

Solid sample size, (φ16—φ20) × (30—50) mm; Powder about 15 (cm3)

Solid sample size, φ20*80 (mm); Powder, liquid sample volume, about 25 (cm3).

Granular, powder sample volume: about 55 (cm3)

5. Calorimetric resolution

0.001℃

0.001℃

0.001℃

0.001℃

6. Calorimeter

Calorimeter heat capacity about 1500J/K, temperature resolution 0.001℃

Calorimeter heat capacity about 1000J/K, temperature resolution 0.001℃

Calorimeter power supply: voltage 0-24V, resolution 1mV; current 0-1A, resolution 0.01mA.

Calorimeter power supply: voltage 0-24V, resolution 1mV; current 0-1A, resolution 0.01mA.

7. Atmosphere environment

Sample oxidation protection: Argon

Sample oxidation protection: Argon

Normal pressure

Vacuum degree: -0.095MPa

8. Experimental method

Mixing method

Mixing method

Adiabatic method

Adiabatic method

9. Power supply

1300℃ specification 220V/50Hz, W≤6KW.

1550℃ specification 380V/50Hz, W≤8KW.

220V/50Hz, power consumption less than 3KW

220V/50Hz, power consumption less than 1KW

220V/50Hz, power consumption less than 1KW

10. Instrument configuration

Includes one BRR-3A high-temperature specific heat capacity tester host, one set of software, one set of communication interface and data cable, one high-precision constant temperature water bath, and one brand desktop computer (configured according to the contract).

Includes one BRR-3B medium-temperature specific heat capacity tester host, one set of software, one set of communication interface and data cable, one high-precision constant temperature water bath, and one brand desktop computer (configured according to the contract).

Includes one BRR-3C room-temperature specific heat capacity tester host, one set of software, one set of communication interface and data cable, one high-precision constant temperature water bath, and one brand desktop computer (configured according to the contract).

Includes one BRR-3D low-temperature specific heat capacity tester host, one set of software, one set of communication interface and data cable, one high-precision constant temperature water bath, one vacuum pump, and one brand desktop computer (configured according to the contract).

11. Measurement and control method

Fully automatic computer testing, data processing, and can generate test reports for printing output.