Product

Daily-Use Ceramic Thermal Stability Tester - Ceramic Testing Instrument


Xiangke RSQ05 Daily Ceramic Thermal Stability Tester - Ceramic Testing Instrument. The thermal stability tester meets GB/T3298-1991 and GB/T3298-2008 standards for the determination of thermal shock resistance of daily-use ceramics and is suitable for determining the thermal stability of daily-use ceramics.

零售价

市场价

库存

Quantity
-
+

库存剩余

隐藏域元素占位

  • 产品描述
    • Commodity name: Daily-Use Ceramic Thermal Stability Tester - Ceramic Testing Instrument
    • Model: Hunan Science and Technology RSQ05

    Xiangke RSQ05 Daily Ceramic Thermal Stability Tester - Ceramic Testing Instrument. The thermal stability tester meets GB/T3298-1991 and GB/T3298-2008 standards for the determination of thermal shock resistance of daily-use ceramics and is suitable for determining the thermal stability of daily-use ceramics.

    Xiangke RSQ05 Daily-use ceramic thermal stability tester - Ceramic testing instrument Thermal stability tester

    This instrument meets the requirements of GB/T3298-1991 and GB/T3298-2008 for the determination of thermal shock resistance of daily-use ceramics. It is suitable for the determination of thermal stability of daily-use ceramics and glass products. It adopts the immersion method to test the thermal stability and thermal shock resistance of ceramic and other materials.

    Xiangke RSQ05 Daily-use ceramic thermal stability tester - Ceramic testing instrument Main technical parameters:

    1. Maximum operating temperature of the furnace body: 300℃;

    2. Size and temperature difference of the uniform temperature zone: 300×300×300 mm, ±5℃; 
    3. Temperature control accuracy: ±5℃ (at 300℃); 
    4. Effective volume (material basket size): 300×300×300 mm; 
    5. Cold furnace heating time: 60 minutes (from room temperature to 300℃); 
    6. Cold material into the furnace temperature rise time: 5 minutes (300℃, material weight 7㎏); 
    7. External dimensions: 1500×1600×850 mm (length × height × width); 
    8. Water tank temperature control range: 15-50℃; 
    9. Temperature control accuracy: ±2℃; 
    10. Water temperature non-uniformity: ±2℃; 
    11. Temperature rise within 5 minutes of hot material entering water: ±4℃ (material temperature 300℃, 7㎏); 
    12. Heating furnace power consumption: 6kw; 
    13. Maximum power consumption of water and electric heater: 4kw; 
    14. Compressor power: 2.2kw; 
    15. Timer range: 0~120 minutes.

    16. Equipped with an electric lifting device, press the lifting button to transfer materials. 
    Working conditions 
    1. Ambient temperature: 0~40℃; 
    2. Power supply: 3×220V, 10kw, 50HZ; 
    3. Cooling water inlet temperature: below 35℃.

    Instrument configuration: including one RSQ05 test host and one sample rack.

Daily-Use Ceramic Thermal Stability Tester - Ceramic Testing Instrument


Model:

Hunan Science and Technology RSQ05

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


Xiangke RSQ05 Daily Ceramic Thermal Stability Tester - Ceramic Testing Instrument. The thermal stability tester meets GB/T3298-1991 and GB/T3298-2008 standards for the determination of thermal shock resistance of daily-use ceramics and is suitable for determining the thermal stability of daily-use ceramics.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

Xiangke RSQ05 Daily-use ceramic thermal stability tester - Ceramic testing instrument Thermal stability tester

This instrument meets the requirements of GB/T3298-1991 and GB/T3298-2008 for the determination of thermal shock resistance of daily-use ceramics. It is suitable for the determination of thermal stability of daily-use ceramics and glass products. It adopts the immersion method to test the thermal stability and thermal shock resistance of ceramic and other materials.

Xiangke RSQ05 Daily-use ceramic thermal stability tester - Ceramic testing instrument Main technical parameters:

1. Maximum operating temperature of the furnace body: 300℃;

2. Size and temperature difference of the uniform temperature zone: 300×300×300 mm, ±5℃; 
3. Temperature control accuracy: ±5℃ (at 300℃); 
4. Effective volume (material basket size): 300×300×300 mm; 
5. Cold furnace heating time: 60 minutes (from room temperature to 300℃); 
6. Cold material into the furnace temperature rise time: 5 minutes (300℃, material weight 7㎏); 
7. External dimensions: 1500×1600×850 mm (length × height × width); 
8. Water tank temperature control range: 15-50℃; 
9. Temperature control accuracy: ±2℃; 
10. Water temperature non-uniformity: ±2℃; 
11. Temperature rise within 5 minutes of hot material entering water: ±4℃ (material temperature 300℃, 7㎏); 
12. Heating furnace power consumption: 6kw; 
13. Maximum power consumption of water and electric heater: 4kw; 
14. Compressor power: 2.2kw; 
15. Timer range: 0~120 minutes.

16. Equipped with an electric lifting device, press the lifting button to transfer materials. 
Working conditions 
1. Ambient temperature: 0~40℃; 
2. Power supply: 3×220V, 10kw, 50HZ; 
3. Cooling water inlet temperature: below 35℃.

Instrument configuration: including one RSQ05 test host and one sample rack.

Relevant Specifications

Relevant Specifications

Inquire

If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!

Submit