Product

Porous Ceramic Channel Diameter Tester


The DZK Multi-porous Ceramic Pore Diameter Tester is suitable for determining the maximum value of the capillary pore channels of multi-porous ceramics according to GB/T1967-1996 "Test Method for Pore Diameter of Multi-porous Ceramics".

零售价

市场价

库存

Quantity
-
+

库存剩余

隐藏域元素占位

  • 产品描述
    • Commodity name: Porous Ceramic Channel Diameter Tester
    • Model: DZK

    The DZK Multi-porous Ceramic Pore Diameter Tester is suitable for determining the maximum value of the capillary pore channels of multi-porous ceramics according to GB/T1967-1996 "Test Method for Pore Diameter of Multi-porous Ceramics".

    Xiangke DZK Porous Ceramic Pore Diameter Tester Pore Diameter Instrument 
    The DKZ porous ceramic pore diameter tester is suitable for determining the maximum value of the capillary pores of porous ceramics according to GB/T1967-1996 "Test Method for Pore Diameter of Porous Ceramics". This instrument mainly consists of three parts: a gas supply cylinder, an electrical control box, and a sample fixture. It uses a precise low-range digital pressure measurement system to accurately measure the test pressure value. The test gas is compressed air or nitrogen; the sample fixture is suitable for cylindrical samples, and the fixture ensures that during the test, the gas can only pass through the capillaries of the sample and not leak from the edges of the sample 
    Xiangke DZK Porous Ceramic Pore Diameter Tester Pore Diameter Instrument Working Principle 
    This method uses the gas bubble pressure method to determine the pore size of the membrane using the principle of capillary action. The surface tension of the wetting agent affects the size of the measured pore size. According to the principle of capillary action, when a capillary with a radius of r is wetted by liquid A with a surface tension of σ, when the relative pressure P2 of the capillary liquid and the gas phase pressure P1 (liquid B is the gas phase) reach static equilibrium, the relationship between P2 and P1 can be described by the Laplace equation: 
    ΔP=P2-P1=2σcosθ/r where θ is the contact angle (cylindrical contact angle is 0) 
    When the pressure difference at both ends of the pore is greater than 2σcosθ/r, the liquid in the capillary will be removed. The gas bubble pressure method is based on this principle to determine the pore size of porous materials. In the actual measurement process, the liquid with known surface tension fully (saturated) wets the pores of the porous ceramic material (vacuum or boiling), and the pressure at one end of the porous material is fixed, while the other end uses air or nitrogen to generate a pressure difference. When the pressure difference reaches a certain value, the largest pore size of the porous material is opened first, and the pore size is calculated according to the above formula. 
    Main Technical Parameters

    1. Flow meter measurement range: 6ml~3600ml/min 
    2. Test pressure 0-2MPa adjustable 
    3. Digital pressure gauge measurement accuracy: ±1%, unit Pa 
    4. Standard sample specifications: Diameter: Ø30±0.5mm 
    5. Supply voltage: 220V 50HZ.

    Configuration: Includes one DKZ test host and one sample fixture.

Porous Ceramic Channel Diameter Tester


Model:

DZK

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


The DZK Multi-porous Ceramic Pore Diameter Tester is suitable for determining the maximum value of the capillary pore channels of multi-porous ceramics according to GB/T1967-1996 "Test Method for Pore Diameter of Multi-porous Ceramics".


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

Xiangke DZK Porous Ceramic Pore Diameter Tester Pore Diameter Instrument 
The DKZ porous ceramic pore diameter tester is suitable for determining the maximum value of the capillary pores of porous ceramics according to GB/T1967-1996 "Test Method for Pore Diameter of Porous Ceramics". This instrument mainly consists of three parts: a gas supply cylinder, an electrical control box, and a sample fixture. It uses a precise low-range digital pressure measurement system to accurately measure the test pressure value. The test gas is compressed air or nitrogen; the sample fixture is suitable for cylindrical samples, and the fixture ensures that during the test, the gas can only pass through the capillaries of the sample and not leak from the edges of the sample 
Xiangke DZK Porous Ceramic Pore Diameter Tester Pore Diameter Instrument Working Principle 
This method uses the gas bubble pressure method to determine the pore size of the membrane using the principle of capillary action. The surface tension of the wetting agent affects the size of the measured pore size. According to the principle of capillary action, when a capillary with a radius of r is wetted by liquid A with a surface tension of σ, when the relative pressure P2 of the capillary liquid and the gas phase pressure P1 (liquid B is the gas phase) reach static equilibrium, the relationship between P2 and P1 can be described by the Laplace equation: 
ΔP=P2-P1=2σcosθ/r where θ is the contact angle (cylindrical contact angle is 0) 
When the pressure difference at both ends of the pore is greater than 2σcosθ/r, the liquid in the capillary will be removed. The gas bubble pressure method is based on this principle to determine the pore size of porous materials. In the actual measurement process, the liquid with known surface tension fully (saturated) wets the pores of the porous ceramic material (vacuum or boiling), and the pressure at one end of the porous material is fixed, while the other end uses air or nitrogen to generate a pressure difference. When the pressure difference reaches a certain value, the largest pore size of the porous material is opened first, and the pore size is calculated according to the above formula. 
Main Technical Parameters

1. Flow meter measurement range: 6ml~3600ml/min 
2. Test pressure 0-2MPa adjustable 
3. Digital pressure gauge measurement accuracy: ±1%, unit Pa 
4. Standard sample specifications: Diameter: Ø30±0.5mm 
5. Supply voltage: 220V 50HZ.

Configuration: Includes one DKZ test host and one sample fixture.

Relevant Specifications

Relevant Specifications

Inquire

If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!

Submit