Flexural Modulus Tester
零售价
$ 4166
市场价
$ 4666
重量
库存剩余
7
隐藏域元素占位
- 产品描述
-
- Commodity name: Flexural Modulus Tester
- Model: Hunan Science and Technology GTM
The Xiangke GTM bending method elastic modulus tester meets the GB/10700-2006 standard "Fine ceramic elastic modulus test method - bending method", and is suitable for the determination of elastic modulus of engineering ceramics, fine ceramics, and functional ceramics at room temperature. 1. Maximum load: 0~10000N; 2. Force measurement accuracy: Relative error ≤ ±0.15%
Xiangke GTM-II-10KN Static Elastic Modulus Tester (Bending Method)
This instrument uses a three-point bending loading method to measure the elastic modulus of non-metallic materials such as ceramics. It consists of an electric loading system, a deformation measurement system, a pressure measurement system, and a computer measurement and control system. The deformation measurement system uses high-precision displacement sensors to measure micro strains; The pressure measurement system adopts high-precision pressure sensors and digital pressure gauges for measurement; The three major measurement and control systems are controlled by computers to achieve fully automatic testing, data processing, and printing of detection reports.
This instrument meets the requirements of GB/10700-2006 "Test Method for Elastic Modulus of Fine Ceramics - Bending Method" and GB/T2326-2009 "Testing of Elastic Limits of Ceramic Plates", and is suitable for the determination of static elastic modulus of non-metallic materials such as engineering ceramics and fine ceramics at room temperature.
Main technical parameters
1. Maximum load: 0~10000N;
2. Force measurement accuracy: relative error ≤ ± 0.15%;
3. Deformation measurement range: ± 5mm;
4. Deformation accuracy: relative error ≤± 0.5%;
5. Loading deformation rate: adjustable from 0 to 1mm/min;
Sample size: ≤ 120 * 100mm (conventional, according to GB/10700-2006);
Or: 820 * 100mm (according to GB/T223266-2009 standard);
(Other specifications can be customized according to user requirements)
7. Voltage: 220V, 50HZ;
Configuration: Includes one GTM-II-10KN testing host, one set of software, one set of testing fixtures, and one desktop computer (configured according to the contract).
Flexural Modulus Tester
Model:
Hunan Science and Technology GTM
Specifications:
Specifications:
这里是占位文字
Gross weight (KG):
The Xiangke GTM bending method elastic modulus tester meets the GB/10700-2006 standard "Fine ceramic elastic modulus test method - bending method", and is suitable for the determination of elastic modulus of engineering ceramics, fine ceramics, and functional ceramics at room temperature. 1. Maximum load: 0~10000N; 2. Force measurement accuracy: Relative error ≤ ±0.15%
Category:
You can send us an email:xtyqyb@163.com
InquireProduct Details
Xiangke GTM-II-10KN Static Elastic Modulus Tester (Bending Method)
This instrument uses a three-point bending loading method to measure the elastic modulus of non-metallic materials such as ceramics. It consists of an electric loading system, a deformation measurement system, a pressure measurement system, and a computer measurement and control system. The deformation measurement system uses high-precision displacement sensors to measure micro strains; The pressure measurement system adopts high-precision pressure sensors and digital pressure gauges for measurement; The three major measurement and control systems are controlled by computers to achieve fully automatic testing, data processing, and printing of detection reports.
This instrument meets the requirements of GB/10700-2006 "Test Method for Elastic Modulus of Fine Ceramics - Bending Method" and GB/T2326-2009 "Testing of Elastic Limits of Ceramic Plates", and is suitable for the determination of static elastic modulus of non-metallic materials such as engineering ceramics and fine ceramics at room temperature.
Main technical parameters
1. Maximum load: 0~10000N;
2. Force measurement accuracy: relative error ≤ ± 0.15%;
3. Deformation measurement range: ± 5mm;
4. Deformation accuracy: relative error ≤± 0.5%;
5. Loading deformation rate: adjustable from 0 to 1mm/min;
Sample size: ≤ 120 * 100mm (conventional, according to GB/10700-2006);
Or: 820 * 100mm (according to GB/T223266-2009 standard);
(Other specifications can be customized according to user requirements)
7. Voltage: 220V, 50HZ;
Configuration: Includes one GTM-II-10KN testing host, one set of software, one set of testing fixtures, and one desktop computer (configured according to the contract).
Relevant Specifications
Relevant Specifications
Recommend
Recommend
Inquire