Product

Graphite Carbon Medium Temperature Thermal Conductivity Tester


Xiangke DR-SM graphite carbon medium-temperature thermal conductivity tester, graphite thermal conductivity tester meets the requirements of GB/T8722-2008 "Determination method of medium-temperature thermal conductivity of graphite materials", applicable to the determination of thermal conductivity of graphite materials in the range of 100~800℃.

零售价

¥ 65000

市场价

¥ 65000

库存

2

  • Specifications
    • DR-SM Graphite Medium Temperature Thermal Conductivity Tester DR-SM Graphite Medium Temperature Thermal Conductivity Tester

You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
Quantity
-
+

库存剩余

2

隐藏域元素占位

  • 产品描述
    • Commodity name: Graphite Carbon Medium Temperature Thermal Conductivity Tester
    • Model: Hunan Xiangke DR-SM

    Xiangke DR-SM graphite carbon medium-temperature thermal conductivity tester, graphite thermal conductivity tester meets the requirements of GB/T8722-2008 "Determination method of medium-temperature thermal conductivity of graphite materials", applicable to the determination of thermal conductivity of graphite materials in the range of 100~800℃.

    Xiangke DR-SM Graphite Carbon Medium Temperature Thermal Conductivity Tester Graphite Thermal Conductivity Instrument

    This instrument meets the requirements of GB/T8722-2008 "Determination Method of Medium Temperature Thermal Conductivity of Graphite Materials", and is suitable for the determination of thermal conductivity of graphite materials in the range of 100~800℃. Computer-aided automatic testing, data processing and printing of test reports. Widely used in production enterprises, research institutes, quality inspection and other departments.

    Xiangke DR-SM Graphite Carbon Medium Temperature Thermal Conductivity Tester Main technical parameters of graphite thermal conductivity instrument:

    Testing temperature range: 100℃~800℃, maximum temperature 1000℃, using digital instrument temperature measurement, accuracy better than 0.2 level;

    Thermal conductivity range: 2~80W/mk,

    DC regulated power supply: 0~500A;0~12V,

    Sample size: ¢16×160 (mm),

    Relative error: ≤±5%,

    Sample oxidation protection method: Vacuum + atmosphere,

    Power supply: 220V/50Hz; Power ≤4KW,

    Computer measurement control, automatic report generation.

    Maximum temperature of electric furnace: 1000℃.

    Product Completeness

    1、DR-SM thermal conductivity test host 1 unit,

    2、Test software 1 set,

    3、Computer (as per contract requirements) 1 set,

    4、Supporting instructions 1 set,

    5、Qualification certificate 1 copy,

    6、DC regulated power supply 1 unit.

Graphite Carbon Medium Temperature Thermal Conductivity Tester


Model:

Hunan Xiangke DR-SM

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


Xiangke DR-SM graphite carbon medium-temperature thermal conductivity tester, graphite thermal conductivity tester meets the requirements of GB/T8722-2008 "Determination method of medium-temperature thermal conductivity of graphite materials", applicable to the determination of thermal conductivity of graphite materials in the range of 100~800℃.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

Xiangke DR-SM Graphite Carbon Medium Temperature Thermal Conductivity Tester Graphite Thermal Conductivity Instrument

This instrument meets the requirements of GB/T8722-2008 "Determination Method of Medium Temperature Thermal Conductivity of Graphite Materials", and is suitable for the determination of thermal conductivity of graphite materials in the range of 100~800℃. Computer-aided automatic testing, data processing and printing of test reports. Widely used in production enterprises, research institutes, quality inspection and other departments.

Xiangke DR-SM Graphite Carbon Medium Temperature Thermal Conductivity Tester Main technical parameters of graphite thermal conductivity instrument:

Testing temperature range: 100℃~800℃, maximum temperature 1000℃, using digital instrument temperature measurement, accuracy better than 0.2 level;

Thermal conductivity range: 2~80W/mk,

DC regulated power supply: 0~500A;0~12V,

Sample size: ¢16×160 (mm),

Relative error: ≤±5%,

Sample oxidation protection method: Vacuum + atmosphere,

Power supply: 220V/50Hz; Power ≤4KW,

Computer measurement control, automatic report generation.

Maximum temperature of electric furnace: 1000℃.

Product Completeness

1、DR-SM thermal conductivity test host 1 unit,

2、Test software 1 set,

3、Computer (as per contract requirements) 1 set,

4、Supporting instructions 1 set,

5、Qualification certificate 1 copy,

6、DC regulated power supply 1 unit.

Relevant Specifications

Relevant Specifications

Inquire

If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!

Submit