  • Specifications
    • DRXL-I Teaching type thermal conductivity meter DRXL-I Teaching type thermal conductivity meter

You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
Quantity
-
+

库存剩余

5

隐藏域元素占位

  • 产品描述
    • Commodity name: Thermal Conductivity Tester - Xiangtan Xiangke Instruments
    • Model: DRXL-Ⅰ

    DRXL-Ⅰ thermal conductivity tester - Xiangtan Xiangke Instrument, can measure the thermal conductivity of various metal and non-metal materials, with a wide testing range.

    DRXL-Ⅰ Thermal Conductivity Tester - Xiangtan Xiangke Instrument Overview:

    Thermal conductivity (thermal conductance) is a physical quantity that reflects the thermal conductivity of a material. It is not only the basis for evaluating the thermal properties of a material, but also a design basis for the application of the material. This parameter is involved in engineering practices such as heater, heat sink, heat transfer pipe design, and house design. Because the thermal conductivity of a material not only changes with temperature and pressure, but also the impurity content and structural changes of the material will significantly affect the value of thermal conductivity, the thermal conductivity of materials is often determined by experimental methods in scientific experiments and engineering technology.

    Methods for measuring thermal conductivity can be roughly divided into two categories: steady-state methods and dynamic methods. This tester uses a steady-state method to measure the thermal conductivity of different materials. Its design concept is clear, simple, and the experimental method is typical and practical. Measuring the thermal conductivity of substances is an important part of thermal experiments.

    This tester consists of a heater, a digital thermometer, a digital timer, etc. (using an integrated design)

    The DRXL-Ⅰ thermal conductivity tester can measure the thermal conductivity of various metal and non-metal materials such as ceramics, rubber, glass, insulation materials, refractory materials, and aluminum alloys, with a wide testing range.

    DRXL-Ⅰ Thermal Conductivity Tester - Xiangtan Xiangke Instrument Main Technical Parameters:

    Power supply: AC (220±10%) V, (50/60) HZ

    Digital thermometer: Measurement accuracy: 0.2% ± 1 digit.

    Digital stopwatch: Timing range: 0~100min; Minimum resolution 1S; Accuracy: 10-5

    Measurement temperature range: Room temperature~500℃ (Maximum heating temperature 550℃)

    Heating voltage: 36VAC

    Heat dissipation copper plate: Radius: 65mm Thickness: 7mm Mass: 815g (The above parameters have been marked on each copper plate, the above are for reference only)

    Test materials: Hard aluminum, rubber, air, etc.

    Continuous working time: >8 hours

Thermal Conductivity Tester - Xiangtan Xiangke Instruments


Model:

DRXL-Ⅰ

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


DRXL-Ⅰ thermal conductivity tester - Xiangtan Xiangke Instrument, can measure the thermal conductivity of various metal and non-metal materials, with a wide testing range.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

DRXL-Ⅰ Thermal Conductivity Tester - Xiangtan Xiangke Instrument Overview:

Thermal conductivity (thermal conductance) is a physical quantity that reflects the thermal conductivity of a material. It is not only the basis for evaluating the thermal properties of a material, but also a design basis for the application of the material. This parameter is involved in engineering practices such as heater, heat sink, heat transfer pipe design, and house design. Because the thermal conductivity of a material not only changes with temperature and pressure, but also the impurity content and structural changes of the material will significantly affect the value of thermal conductivity, the thermal conductivity of materials is often determined by experimental methods in scientific experiments and engineering technology.

Methods for measuring thermal conductivity can be roughly divided into two categories: steady-state methods and dynamic methods. This tester uses a steady-state method to measure the thermal conductivity of different materials. Its design concept is clear, simple, and the experimental method is typical and practical. Measuring the thermal conductivity of substances is an important part of thermal experiments.

This tester consists of a heater, a digital thermometer, a digital timer, etc. (using an integrated design)

The DRXL-Ⅰ thermal conductivity tester can measure the thermal conductivity of various metal and non-metal materials such as ceramics, rubber, glass, insulation materials, refractory materials, and aluminum alloys, with a wide testing range.

DRXL-Ⅰ Thermal Conductivity Tester - Xiangtan Xiangke Instrument Main Technical Parameters:

Power supply: AC (220±10%) V, (50/60) HZ

Digital thermometer: Measurement accuracy: 0.2% ± 1 digit.

Digital stopwatch: Timing range: 0~100min; Minimum resolution 1S; Accuracy: 10-5

Measurement temperature range: Room temperature~500℃ (Maximum heating temperature 550℃)

Heating voltage: 36VAC

Heat dissipation copper plate: Radius: 65mm Thickness: 7mm Mass: 815g (The above parameters have been marked on each copper plate, the above are for reference only)

Test materials: Hard aluminum, rubber, air, etc.

Continuous working time: >8 hours

Relevant Specifications