The multi-element rapid analyzer is equipped with the company's newly developed anti-interference technology, which can accurately and rapidly quantitatively analyze the content of more than 20 elements over a wide range. It has significant advantages in the field of silicate system analysis, and is particularly suitable for quantitative analysis in non-metallic industries such as ceramics, refractory materials, cement, and glass, as well as in the colored metal and smelting industries such as tungsten, molybdenum, nickel, cobalt, and copper.

零售价

¥ 45000

市场价

¥ 45000

库存

5

  • Specifications
    • DHF186 multi-element rapid analyzer standard configuration DHF186 multi-element rapid analyzer standard configuration

You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
Quantity
-
+

库存剩余

5

隐藏域元素占位

  • 产品描述
    • Commodity name: Multi-element Rapid Analyzer
    • Model: New DHF186

    The multi-element rapid analyzer is equipped with the company's newly developed anti-interference technology, which can accurately and rapidly quantitatively analyze the content of more than 20 elements over a wide range. It has significant advantages in the field of silicate system analysis, and is particularly suitable for quantitative analysis in non-metallic industries such as ceramics, refractory materials, cement, and glass, as well as in the colored metal and smelting industries such as tungsten, molybdenum, nickel, cobalt, and copper.

    Xiangkexin DHF186 Series Multi-element Rapid Analyzer

    1. Overview

    Multi-element Rapid Analyzer Based on the Type 85, it incorporates an automatic rotary mixing system for solutions and samples, simulating manual mixing while eliminating this time-consuming and precision-controlled step. Simultaneously, the manual movements in three-dimensional space (up/down, forward/backward, left/right) are automated, significantly improving analysis speed and ease of operation. It is particularly suitable for rapid analysis of large samples. 
      2. Main Technical Parameters of the Element Rapid Analyzer

    2.1 Measurable Elements and Ranges

    SiO2 0.01~99.9% Al2O3 0.01~99.9% Fe2O3 0.01~99.9% TiO2 0.01~99.9%

    K2O 0.01~15% Na2O 0.01~15% CaO 0.01~99.9% MgO 0.01~99.9%

    B2O3 0.01~30% ZrO2 0.01~99.9% Li2O 0.01~15% SnO 0.01~99.9%

    PbO 0.01~99% ZnO 0.01~99.9% MnO 0.01~15% Cr2O3 0.01~15%

    BaO 0.01~10% NiO 0.01~99.9% CoO 0.01~99.9% P2O5 0.01~30%

    MoO3 0.01~99.9% V2O5 0.01~99.9% CuO 0.01~99.9% Mo 0.01~99.9%

    If special needs arise, the lower limit of the content measurement for some of these elements can be extended to 0.001%.

    2.2 Measurable Substance Types

    2.2.1 Silicates and Aluminosilicates:

    Ceramic raw materials (including glazes) and finished products, refractory raw materials and finished products, glass raw materials (including glass-ceramics) and finished products, main cement raw materials and finished products, and other inorganic non-metallic materials.

    2.2.2 The following non-ferrous metal minerals, alloys, and main components of chemical raw materials can be measured:

    Chromium salt products, V2O5 products, MnO products, NiO products, titanium dioxide, phosphates, cobalt oxide, zinc oxide, boric acid, borax, barium carbonate, water glass, sodium humate, red lead, iron oxide, molybdenum trioxide, molybdic salts, molybdenum ore, ferromolybdenum, molybdenum-nickel alloy, nickel-cobalt-copper alloy, etc.

    2.3 Sampling Channels: 7

    2.4 Measurement Channels: 6

    2.5 Measurement Stability: The reading changes within ±2 digits within 5 minutes.

    2.6 Test Repeatability: The reading of the same sample solution in 20 repeated measurements is ±1*

    2.7 Detection Speed:

    Approximately 2 hours are required to complete the determination of SiO2, Al2O3, Fe2O3, TiO2, K2O, Na2O, CaO, and MgO in 4 conventional samples from the start of weighing. The determination of other elements can be completed within 4-6 hours.

    2.8 Number of Continuously Measurable Samples: 10

    3. Instrument Operating Conditions:

    Power Supply 220V 50Hz

    Total Power 1KW

    Ambient Temperature 25±5℃

    Relative Humidity ≤85%

      4. Xiangkexin DHF186 Series List Element Rapid Analyzer Instrument Configuration:

    DHF186 analyzer host: 1 unit;

    Data processing system: 1 set (including 1 computer, 1 software, 1 printer);

    Flame photometer: 1 set;

    30ml silver crucible: 4 sets;

    Ultrasonic cleaner: 1 unit;

    Oscillator: 1 unit;

    Standard stock solution: 1 set (limited to conventional 8 elements).

Multi-element Rapid Analyzer


Model:

New DHF186

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


The multi-element rapid analyzer is equipped with the company's newly developed anti-interference technology, which can accurately and rapidly quantitatively analyze the content of more than 20 elements over a wide range. It has significant advantages in the field of silicate system analysis, and is particularly suitable for quantitative analysis in non-metallic industries such as ceramics, refractory materials, cement, and glass, as well as in the colored metal and smelting industries such as tungsten, molybdenum, nickel, cobalt, and copper.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

Xiangkexin DHF186 Series Multi-element Rapid Analyzer

1. Overview

Multi-element Rapid Analyzer Based on the Type 85, it incorporates an automatic rotary mixing system for solutions and samples, simulating manual mixing while eliminating this time-consuming and precision-controlled step. Simultaneously, the manual movements in three-dimensional space (up/down, forward/backward, left/right) are automated, significantly improving analysis speed and ease of operation. It is particularly suitable for rapid analysis of large samples. 
  2. Main Technical Parameters of the Element Rapid Analyzer

2.1 Measurable Elements and Ranges

SiO2 0.01~99.9% Al2O3 0.01~99.9% Fe2O3 0.01~99.9% TiO2 0.01~99.9%

K2O 0.01~15% Na2O 0.01~15% CaO 0.01~99.9% MgO 0.01~99.9%

B2O3 0.01~30% ZrO2 0.01~99.9% Li2O 0.01~15% SnO 0.01~99.9%

PbO 0.01~99% ZnO 0.01~99.9% MnO 0.01~15% Cr2O3 0.01~15%

BaO 0.01~10% NiO 0.01~99.9% CoO 0.01~99.9% P2O5 0.01~30%

MoO3 0.01~99.9% V2O5 0.01~99.9% CuO 0.01~99.9% Mo 0.01~99.9%

If special needs arise, the lower limit of the content measurement for some of these elements can be extended to 0.001%.

2.2 Measurable Substance Types

2.2.1 Silicates and Aluminosilicates:

Ceramic raw materials (including glazes) and finished products, refractory raw materials and finished products, glass raw materials (including glass-ceramics) and finished products, main cement raw materials and finished products, and other inorganic non-metallic materials.

2.2.2 The following non-ferrous metal minerals, alloys, and main components of chemical raw materials can be measured:

Chromium salt products, V2O5 products, MnO products, NiO products, titanium dioxide, phosphates, cobalt oxide, zinc oxide, boric acid, borax, barium carbonate, water glass, sodium humate, red lead, iron oxide, molybdenum trioxide, molybdic salts, molybdenum ore, ferromolybdenum, molybdenum-nickel alloy, nickel-cobalt-copper alloy, etc.

2.3 Sampling Channels: 7

2.4 Measurement Channels: 6

2.5 Measurement Stability: The reading changes within ±2 digits within 5 minutes.

2.6 Test Repeatability: The reading of the same sample solution in 20 repeated measurements is ±1*

2.7 Detection Speed:

Approximately 2 hours are required to complete the determination of SiO2, Al2O3, Fe2O3, TiO2, K2O, Na2O, CaO, and MgO in 4 conventional samples from the start of weighing. The determination of other elements can be completed within 4-6 hours.

2.8 Number of Continuously Measurable Samples: 10

3. Instrument Operating Conditions:

Power Supply 220V 50Hz

Total Power 1KW

Ambient Temperature 25±5℃

Relative Humidity ≤85%

  4. Xiangkexin DHF186 Series List Element Rapid Analyzer Instrument Configuration:

DHF186 analyzer host: 1 unit;

Data processing system: 1 set (including 1 computer, 1 software, 1 printer);

Flame photometer: 1 set;

30ml silver crucible: 4 sets;

Ultrasonic cleaner: 1 unit;

Oscillator: 1 unit;

Standard stock solution: 1 set (limited to conventional 8 elements).