Multi-element Chemical Composition Rapid Analyzer
零售价
¥ 40000
市场价
¥ 40000
库存
5
-
Specifications
-
DHF83B multi-element rapid analyzer standard configuration
-
You can send us an email:xtyqyb@163.com
Inquire库存剩余
5
隐藏域元素占位
- 产品描述
-
- Commodity name: Multi-element Chemical Composition Rapid Analyzer
- Model: DHF83B
The DHF83B multi-element rapid analyzer, a multi-element chemical composition rapid analyzer, has significant advantages in the field of silicate system analysis, and is particularly suitable for quantitative analysis in non-metallic industries such as ceramics, refractory materials, cement, and glass, as well as in the colored metal and smelting industries such as tungsten, molybdenum, nickel, cobalt, and copper.
DHF83B Multi-element rapid analyzer, chemical composition Analyzer Ceramic raw material analyzer
1、 DHF83B Rapid multi-element chemical composition Analyzer Overview
DHF83B Rapid multi-element chemical composition Analyzer This is a new high-tech product developed based on the DHF82 multi-element rapid analyzer! It adopts a * linear expansion and sensitivity improvement method, solving the problem that ordinary photometric analysis of high component content deviates from linearity and the sensitivity of low component content analysis is poor. It is equipped with a 6-channel automatic precision liquid adding system, a 6-element synchronous measurement system, and an automatic data processing system. It is also equipped with a new anti-interference technology developed by the company, which can accurately and quickly quantitatively analyze the content of more than 20 elements in a wide range. The instrument has the characteristics of small error, high precision, simple operation, and low operating cost; it has significant advantages in the field of silicate system analysis, and is particularly suitable for quantitative analysis in the non-metallic industries such as ceramics, refractory materials, cement, and glass, and the colored metal and smelting industries such as tungsten, molybdenum, nickel, cobalt, and copper. This product has been widely used in colleges and universities, scientific research institutes, factories and mines, and is widely sold to Southeast Asia, Taiwan, China and other countries and regions. All have received good results.
2 Main technical parameters
2.1 Measurable elements and ranges
SiO2 0.01~99.9% Al2O3 0.01~99.9% Fe2O3 0.01~99.9% TiO2 0.01~99.9%
K2O 0.01~15% Na2O 0.01~15% CaO 0.01~99.9% MgO 0.01~99.9%
B2O3 0.01~30% ZrO2 0.01~99.9% Li2O 0.01~15% SnO 0.01~15%
PbO 0.01~99.9% ZnO 0.01~99.9% MnO 0.01~15% Cr2O3 0.01~15%
BaO 0.01~10% NiO 0.01~99.9% CoO 0.01~99.9% P2O5 0.01~30%
MoO3 0.01~99.9% V2O5 0.01~99.9% CuO 0.01~99.9% Mo 0.01~99.9%
If there are special needs, the lower limit of the content measurement of some elements can be extended to 0.001%
2.2 Types of measurable substances
2.2.1 Silicate and aluminate:
Ceramic raw materials (including glazes) and finished products, refractory material raw materials and finished products, glass raw materials (including microcrystalline glass) and finished products, main raw materials and finished products of cement, and other inorganic non-metallic materials, etc.
2.2.2 The main components of the following non-ferrous metal minerals and alloys and chemical raw materials can be determined:
Chromium salt products, V2O5 products, MnO products, NiO products, titanium powder, phosphate, cobalt oxide, zinc oxide, boric acid, borax, barium carbonate, water glass, sodium humate, red lead, iron oxide, molybdenum trioxide, molybdate, molybdenum ore, ferromolybdenum alloy, molybdenum nickel alloy, nickel cobalt copper alloy, etc.
2.3 Sampling channels: 6
2.4 Measurement channels: 6.
2.5 Measurement stability: The reading change within 5 minutes is ±2 digits.
2.6 Test repeatability: The reading of the same sample solution in 20 repeated measurements is ±1*
2.7 Detection speed:
It takes about 2 hours to complete the determination of SiO2, Al2O3, Fe2O3, TiO2, K2O, Na2O, CaO, and MgO in 4 conventional samples from the start of weighing. The determination of other elements can be completed within 4-6 hours.
2.8 Number of continuously measured samples: 10.
3 Instrument operating conditions:
Power supply 220V 50Hz
Total power 1KW
Ambient temperature 25±5℃
Relative humidity ≤85%
4 Instrument configuration:
DHF83B analyzer host: 1 unit;
Data processing system: 1 set (1 computer, 1 printer, 1 software);
Flame photometer: 1 set;
Silver crucible: 4 sets;
Ultrasonic cleaner: 1 unit;
Standard stock solution: 1 set (limited to conventional 8 elements).
Multi-element Chemical Composition Rapid Analyzer
Model:
DHF83B
Specifications:
Specifications:
这里是占位文字
Gross weight (KG):
The DHF83B multi-element rapid analyzer, a multi-element chemical composition rapid analyzer, has significant advantages in the field of silicate system analysis, and is particularly suitable for quantitative analysis in non-metallic industries such as ceramics, refractory materials, cement, and glass, as well as in the colored metal and smelting industries such as tungsten, molybdenum, nickel, cobalt, and copper.
Category:
You can send us an email:xtyqyb@163.com
InquireProduct Details
DHF83B Multi-element rapid analyzer, chemical composition Analyzer Ceramic raw material analyzer
1、 DHF83B Rapid multi-element chemical composition Analyzer Overview
DHF83B Rapid multi-element chemical composition Analyzer This is a new high-tech product developed based on the DHF82 multi-element rapid analyzer! It adopts a * linear expansion and sensitivity improvement method, solving the problem that ordinary photometric analysis of high component content deviates from linearity and the sensitivity of low component content analysis is poor. It is equipped with a 6-channel automatic precision liquid adding system, a 6-element synchronous measurement system, and an automatic data processing system. It is also equipped with a new anti-interference technology developed by the company, which can accurately and quickly quantitatively analyze the content of more than 20 elements in a wide range. The instrument has the characteristics of small error, high precision, simple operation, and low operating cost; it has significant advantages in the field of silicate system analysis, and is particularly suitable for quantitative analysis in the non-metallic industries such as ceramics, refractory materials, cement, and glass, and the colored metal and smelting industries such as tungsten, molybdenum, nickel, cobalt, and copper. This product has been widely used in colleges and universities, scientific research institutes, factories and mines, and is widely sold to Southeast Asia, Taiwan, China and other countries and regions. All have received good results.
2 Main technical parameters
2.1 Measurable elements and ranges
SiO2 0.01~99.9% Al2O3 0.01~99.9% Fe2O3 0.01~99.9% TiO2 0.01~99.9%
K2O 0.01~15% Na2O 0.01~15% CaO 0.01~99.9% MgO 0.01~99.9%
B2O3 0.01~30% ZrO2 0.01~99.9% Li2O 0.01~15% SnO 0.01~15%
PbO 0.01~99.9% ZnO 0.01~99.9% MnO 0.01~15% Cr2O3 0.01~15%
BaO 0.01~10% NiO 0.01~99.9% CoO 0.01~99.9% P2O5 0.01~30%
MoO3 0.01~99.9% V2O5 0.01~99.9% CuO 0.01~99.9% Mo 0.01~99.9%
If there are special needs, the lower limit of the content measurement of some elements can be extended to 0.001%
2.2 Types of measurable substances
2.2.1 Silicate and aluminate:
Ceramic raw materials (including glazes) and finished products, refractory material raw materials and finished products, glass raw materials (including microcrystalline glass) and finished products, main raw materials and finished products of cement, and other inorganic non-metallic materials, etc.
2.2.2 The main components of the following non-ferrous metal minerals and alloys and chemical raw materials can be determined:
Chromium salt products, V2O5 products, MnO products, NiO products, titanium powder, phosphate, cobalt oxide, zinc oxide, boric acid, borax, barium carbonate, water glass, sodium humate, red lead, iron oxide, molybdenum trioxide, molybdate, molybdenum ore, ferromolybdenum alloy, molybdenum nickel alloy, nickel cobalt copper alloy, etc.
2.3 Sampling channels: 6
2.4 Measurement channels: 6.
2.5 Measurement stability: The reading change within 5 minutes is ±2 digits.
2.6 Test repeatability: The reading of the same sample solution in 20 repeated measurements is ±1*
2.7 Detection speed:
It takes about 2 hours to complete the determination of SiO2, Al2O3, Fe2O3, TiO2, K2O, Na2O, CaO, and MgO in 4 conventional samples from the start of weighing. The determination of other elements can be completed within 4-6 hours.
2.8 Number of continuously measured samples: 10.
3 Instrument operating conditions:
Power supply 220V 50Hz
Total power 1KW
Ambient temperature 25±5℃
Relative humidity ≤85%
4 Instrument configuration:
DHF83B analyzer host: 1 unit;
Data processing system: 1 set (1 computer, 1 printer, 1 software);
Flame photometer: 1 set;
Silver crucible: 4 sets;
Ultrasonic cleaner: 1 unit;
Standard stock solution: 1 set (limited to conventional 8 elements).
Relevant Specifications
Relevant Specifications
Recommend
Recommend
Inquire
If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!