Product

Silicate Analyzer


The GKF series silicate analyzer and silicate chemical composition analyzer are new photometric analyzers developed based on the principle of photometric analysis. They are suitable for the systematic analysis of silicate chemical composition and are also applicable in the testing fields of refractory materials, building materials, geological and mineral materials, and their products.

零售价

¥ 38000

市场价

¥ 38000

库存

5

  • Specifications
    • GKF Silicate Chemical Composition Rapid Analyzer GKF Silicate Chemical Composition Rapid Analyzer

You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
Quantity
-
+

库存剩余

5

隐藏域元素占位

  • 产品描述
    • Commodity name: Silicate Analyzer
    • Model: GKF series

    The GKF series silicate analyzer and silicate chemical composition analyzer are new photometric analyzers developed based on the principle of photometric analysis. They are suitable for the systematic analysis of silicate chemical composition and are also applicable in the testing fields of refractory materials, building materials, geological and mineral materials, and their products.

    Xiangtan Xiangke GKF Series Silicate Analyzer Silicate Chemical Composition Analyzer

    The instrument is a new type of photometric analyzer developed based on the principle of photometric analysis. Using advanced technology, it maintains excellent linearity accuracy over a wide concentration range. Employing a computer data processing system, it is more suitable for the simultaneous determination of multiple samples (up to 10 samples at a time). All knobs and switches have been eliminated; no knobs need to be adjusted. All functions are software-controlled, including automatic zeroing and automatic linear correction. This fundamentally avoids mechanical failures, greatly improving instrument stability and simplifying operation. Essentially zero maintenance is required. It is particularly suitable for the systematic analysis of silicate chemical composition and is also suitable for the testing of refractory materials, building materials, geological and mineral products, etc.

    Measurement Range:

    1. Full analysis of ceramic raw materials such as feldspar, clay, kaolin, limestone, dolomite, calcite, bauxite, and quartz. The determination ranges for each component are as follows:

    SiO2 0.10~95.00% K2O 0.10~15.00% 
    Al2O3 0.10~95.00% Na2O 0.10~15.00% 
    Fe2O3 0.10~15.00% CaO 0.10~60.00% 
    TiO2 0.10~15.00% MgO 0.10~60.00%

    2. Quartz (SiO2 > 98.00%, platinum crucible required for this item) 
    3. Zirconium, silicon, iron, and titanium in zircon; 
    4. Eight conventional elements and zirconium, cobalt, lead, boron, barium, zinc, and chromium in frit glaze; 
    5. Eight conventional elements and lithium in spodumene and lithium feldspar; 
    6. TiO2 in titanium powder; 
    7. P2O5 in ceramic raw materials 
    8. Manganese oxide chemical raw materials; 
    9. CoO in cobalt oxide and cobalt acetate chemical raw materials; 
    10. NiO in nickel oxide and nickel acetate chemical raw materials; 
    11. ZnO in zinc oxide chemical raw materials; 
    12. Barium oxide chemical raw materials; 
    13. CuO in copper acetate chemical raw materials; 
    14. Cr2O3 in chromium salts; 
    15. Fe2O3 in iron salts (penetration colorants); 
    16. Low-content components in the electrical porcelain and glass industry:

    Fe2O3 (0.005%~0.200%) K2O (0.02%~0.10%) Na2O (0.02%~0.10%) 
    P2O5 (0.02%~0.10%) Mn (0.02%~20%) Co (0.10%~70%) 
    Cr2O3 (0.10%~40%) Cd (0.02%~0.5%); 
    Silicate Analyzer Technical Indicators:

    1. Accuracy: The measurement accuracy of this equipment can reach or exceed the accuracy requirements for relevant elements in national analysis method standards (GB/T4734-1996, QB/T 2578-2002). 
    2. Analysis Speed: From sample weighing, the entire chemical composition analysis process for 8 conventional items is completed in 2-3 hours. Analysis of all items is completed in 4-5 hours. 
    3. Maximum number of samples for simultaneous determination: 9

    Instrument Completeness:

    1. One main measuring instrument; 
    2. One set of data processing system; 
    3. One set of 6400A flame photometer 
    4. Two sets of silver crucibles (30ml/set) 
    5. One ultrasonic cleaner (50W); 
    Working Environment: 
    1. Ambient temperature: 5℃~35℃, 
      Relative humidity: ≤85% 
    2. Operating power supply: 220±22V, 50Hz, 
      Installed capacity: 3KVA 
    3. Installation table: 3.5×0.8m work surface

Silicate Analyzer


Model:

GKF series

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


The GKF series silicate analyzer and silicate chemical composition analyzer are new photometric analyzers developed based on the principle of photometric analysis. They are suitable for the systematic analysis of silicate chemical composition and are also applicable in the testing fields of refractory materials, building materials, geological and mineral materials, and their products.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

Xiangtan Xiangke GKF Series Silicate Analyzer Silicate Chemical Composition Analyzer

The instrument is a new type of photometric analyzer developed based on the principle of photometric analysis. Using advanced technology, it maintains excellent linearity accuracy over a wide concentration range. Employing a computer data processing system, it is more suitable for the simultaneous determination of multiple samples (up to 10 samples at a time). All knobs and switches have been eliminated; no knobs need to be adjusted. All functions are software-controlled, including automatic zeroing and automatic linear correction. This fundamentally avoids mechanical failures, greatly improving instrument stability and simplifying operation. Essentially zero maintenance is required. It is particularly suitable for the systematic analysis of silicate chemical composition and is also suitable for the testing of refractory materials, building materials, geological and mineral products, etc.

Measurement Range:

1. Full analysis of ceramic raw materials such as feldspar, clay, kaolin, limestone, dolomite, calcite, bauxite, and quartz. The determination ranges for each component are as follows:

SiO2 0.10~95.00% K2O 0.10~15.00% 
Al2O3 0.10~95.00% Na2O 0.10~15.00% 
Fe2O3 0.10~15.00% CaO 0.10~60.00% 
TiO2 0.10~15.00% MgO 0.10~60.00%

2. Quartz (SiO2 > 98.00%, platinum crucible required for this item) 
3. Zirconium, silicon, iron, and titanium in zircon; 
4. Eight conventional elements and zirconium, cobalt, lead, boron, barium, zinc, and chromium in frit glaze; 
5. Eight conventional elements and lithium in spodumene and lithium feldspar; 
6. TiO2 in titanium powder; 
7. P2O5 in ceramic raw materials 
8. Manganese oxide chemical raw materials; 
9. CoO in cobalt oxide and cobalt acetate chemical raw materials; 
10. NiO in nickel oxide and nickel acetate chemical raw materials; 
11. ZnO in zinc oxide chemical raw materials; 
12. Barium oxide chemical raw materials; 
13. CuO in copper acetate chemical raw materials; 
14. Cr2O3 in chromium salts; 
15. Fe2O3 in iron salts (penetration colorants); 
16. Low-content components in the electrical porcelain and glass industry:

Fe2O3 (0.005%~0.200%) K2O (0.02%~0.10%) Na2O (0.02%~0.10%) 
P2O5 (0.02%~0.10%) Mn (0.02%~20%) Co (0.10%~70%) 
Cr2O3 (0.10%~40%) Cd (0.02%~0.5%); 
Silicate Analyzer Technical Indicators:

1. Accuracy: The measurement accuracy of this equipment can reach or exceed the accuracy requirements for relevant elements in national analysis method standards (GB/T4734-1996, QB/T 2578-2002). 
2. Analysis Speed: From sample weighing, the entire chemical composition analysis process for 8 conventional items is completed in 2-3 hours. Analysis of all items is completed in 4-5 hours. 
3. Maximum number of samples for simultaneous determination: 9

Instrument Completeness:

1. One main measuring instrument; 
2. One set of data processing system; 
3. One set of 6400A flame photometer 
4. Two sets of silver crucibles (30ml/set) 
5. One ultrasonic cleaner (50W); 
Working Environment: 
1. Ambient temperature: 5℃~35℃, 
  Relative humidity: ≤85% 
2. Operating power supply: 220±22V, 50Hz, 
  Installed capacity: 3KVA 
3. Installation table: 3.5×0.8m work surface

Relevant Specifications

Relevant Specifications

Inquire

If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!

Submit