Product

Glass Chemical Composition Analyzer


The DHF84 Glass Chemical Composition Analyzer (Multi-element Rapid Analyzer) utilizes scientific research achievements and has obtained a new national patent, No. 201120329943.0, which is the company's proprietary intellectual property. Its high-precision liquid dispensing system has a dispensing accuracy 3 times that of the DHF83 model, and a detection speed 2 times that of the DHF83 model. It is particularly suitable for quantitative analysis in non-metallic industries such as ceramics, refractory materials, cement, and glass, as well as in the colored metal and smelting industries such as tungsten, molybdenum, nickel, cobalt, and copper.

零售价

¥ 40000

市场价

¥ 40000

库存

20

  • Specifications
    • DHF84 multi-element rapid analyzer standard configuration DHF84 multi-element rapid analyzer standard configuration
    • DHF84 multi-element rapid analyzer analysis host DHF84 multi-element rapid analyzer standard configuration

You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
Quantity
-
+

库存剩余

20

隐藏域元素占位

  • 产品描述
    • Commodity name: Glass Chemical Composition Analyzer
    • Model: DHF84

    The DHF84 Glass Chemical Composition Analyzer (Multi-element Rapid Analyzer) utilizes scientific research achievements and has obtained a new national patent, No. 201120329943.0, which is the company's proprietary intellectual property. Its high-precision liquid dispensing system has a dispensing accuracy 3 times that of the DHF83 model, and a detection speed 2 times that of the DHF83 model. It is particularly suitable for quantitative analysis in non-metallic industries such as ceramics, refractory materials, cement, and glass, as well as in the colored metal and smelting industries such as tungsten, molybdenum, nickel, cobalt, and copper.

    DHF84 Multi-element Rapid Analyzer, Glass Chemical Composition Analyzer

    1. DHF84 Multi-element Rapid Analyzer, Glass Chemical Composition Analyzer Overview

    The DHF84 multi-element rapid analyzer adopts a * linear expansion and sensitivity enhancement method, solving the problem of deviation from linearity in the analysis of high-component content by ordinary photometry and poor sensitivity in the analysis of low-component content. It is a high-tech new product developed based on the DHF83 multi-element rapid analyzer! Using scientific research achievements, it has obtained a new national patent number: 201120329943.0, which is the company's * intellectual property right. Its high-precision liquid adding system has a liquid adding precision 3 times that of the DHF83 type, and the detection speed is 2 times that of the DHF83 type. The analysis is more accurate, faster, more intelligent, easier to operate, and less expensive! It is equipped with a 7-channel automatic precision liquid adding system, a 6-element synchronous measurement system, and an automatic data processing system. It is also equipped with the company's newly developed anti-interference technology, which can accurately and quickly quantitatively analyze the content of more than 20 elements in a wide range. It has significant advantages in the field of silicate system analysis, and is particularly suitable for quantitative analysis in the non-metallic industries such as ceramics, refractory materials, cement, and glass, and the non-ferrous metal and smelting industries such as tungsten, molybdenum, nickel, cobalt, and copper. This product is widely used in colleges and universities, research institutes, factories and mines, and is widely sold to Southeast Asia, Taiwan, China and other countries and regions. All have received good results.

    2 DHF84 Multi-element Rapid Analyzer, Main Technical Parameters

    2.1 Measurable Elements and Ranges

    SiO2 0.01~99.9% Al2O3 0.01~99.9% Fe2O3 0.01~99.9% TiO2 0.01~99.9%

    K2O 0.01~15% Na2O 0.01~15% CaO 0.01~99.9% MgO 0.01~99.9%

    B2O3 0.01~30% ZrO2 0.01~99.9% Li2O 0.01~15% SnO 0.01~15%

    PbO 0.01~99.9% ZnO 0.01~99.9% MnO 0.01~15% Cr2O3 0.01~15%

    BaO 0.01~10% NiO 0.01~99.9% CoO 0.01~99.9% P2O5 0.01~30%

    MoO3 0.01~99.9% V2O5 0.01~99.9% CuO 0.01~99.9% Mo 0.01~99.9%

    If special needs, the lower limit of the content measurement of some elements can be extended to 0.001%.

    2.2 Types of Measurable Substances

    2.2.1 Silicate and Aluminosilicate:

    Ceramic raw materials (including glazes) and finished products, refractory material raw materials and finished products, glass raw materials (including microcrystalline glass) and finished products, cement main raw materials and finished products, and other inorganic non-metallic materials.

    2.2.2 The following non-ferrous metal minerals and alloys and main components of chemical raw materials can be determined:

    Chromium salt products, V2O5 products, MnO products, NiO products, titanium powder, phosphate, cobalt oxide, zinc oxide, boric acid, borax, barium carbonate, water glass, sodium humate, red lead, iron oxide, molybdenum trioxide, molybdate, molybdenum ore, ferro-molybdenum alloy, molybdenum-nickel alloy, nickel-cobalt-copper alloy, etc.

    2.3 Sampling Channels: 7

    2.4 Measurement Channels: 6.

    2.5 Measurement Stability: The reading changes ±2 digits within 5 minutes.

    2.6 Test Repeatability: The reading of the same sample solution in 20 repeated measurements is ±1*

    2.7 Detection Speed:

    From the beginning of weighing, it takes about 2 hours to complete the determination of SiO2, Al2O3, Fe2O3, TiO2, K2O, Na2O, CaO, and MgO in 4 conventional samples. The determination of other elements can be completed within 4-6 hours.

    2.8 Number of continuously measured samples: More than 10.

    3. DHF84 Multi-element Rapid Analyzer, Instrument Operating Conditions:

    Power Supply 220V 50Hz

    Total Power 1KW

    Ambient Temperature 25±5℃

    Relative Humidity ≤85%

    4. DHF84 Multi-element Rapid Analyzer, Instrument Configuration:

    DHF84 analyzer host: 1 unit;

    Data processing system: 1 set (1 computer, 1 printer, 1 software);

    Flame photometer: 1 set;

    30ml silver crucible: 4 sets;

    Ultrasonic cleaner: 1 unit;

    Standard stock solution: 1 set (limited to conventional 8 elements).

Glass Chemical Composition Analyzer


Model:

DHF84

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


The DHF84 Glass Chemical Composition Analyzer (Multi-element Rapid Analyzer) utilizes scientific research achievements and has obtained a new national patent, No. 201120329943.0, which is the company's proprietary intellectual property. Its high-precision liquid dispensing system has a dispensing accuracy 3 times that of the DHF83 model, and a detection speed 2 times that of the DHF83 model. It is particularly suitable for quantitative analysis in non-metallic industries such as ceramics, refractory materials, cement, and glass, as well as in the colored metal and smelting industries such as tungsten, molybdenum, nickel, cobalt, and copper.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

DHF84 Multi-element Rapid Analyzer, Glass Chemical Composition Analyzer

1. DHF84 Multi-element Rapid Analyzer, Glass Chemical Composition Analyzer Overview

The DHF84 multi-element rapid analyzer adopts a * linear expansion and sensitivity enhancement method, solving the problem of deviation from linearity in the analysis of high-component content by ordinary photometry and poor sensitivity in the analysis of low-component content. It is a high-tech new product developed based on the DHF83 multi-element rapid analyzer! Using scientific research achievements, it has obtained a new national patent number: 201120329943.0, which is the company's * intellectual property right. Its high-precision liquid adding system has a liquid adding precision 3 times that of the DHF83 type, and the detection speed is 2 times that of the DHF83 type. The analysis is more accurate, faster, more intelligent, easier to operate, and less expensive! It is equipped with a 7-channel automatic precision liquid adding system, a 6-element synchronous measurement system, and an automatic data processing system. It is also equipped with the company's newly developed anti-interference technology, which can accurately and quickly quantitatively analyze the content of more than 20 elements in a wide range. It has significant advantages in the field of silicate system analysis, and is particularly suitable for quantitative analysis in the non-metallic industries such as ceramics, refractory materials, cement, and glass, and the non-ferrous metal and smelting industries such as tungsten, molybdenum, nickel, cobalt, and copper. This product is widely used in colleges and universities, research institutes, factories and mines, and is widely sold to Southeast Asia, Taiwan, China and other countries and regions. All have received good results.

2 DHF84 Multi-element Rapid Analyzer, Main Technical Parameters

2.1 Measurable Elements and Ranges

SiO2 0.01~99.9% Al2O3 0.01~99.9% Fe2O3 0.01~99.9% TiO2 0.01~99.9%

K2O 0.01~15% Na2O 0.01~15% CaO 0.01~99.9% MgO 0.01~99.9%

B2O3 0.01~30% ZrO2 0.01~99.9% Li2O 0.01~15% SnO 0.01~15%

PbO 0.01~99.9% ZnO 0.01~99.9% MnO 0.01~15% Cr2O3 0.01~15%

BaO 0.01~10% NiO 0.01~99.9% CoO 0.01~99.9% P2O5 0.01~30%

MoO3 0.01~99.9% V2O5 0.01~99.9% CuO 0.01~99.9% Mo 0.01~99.9%

If special needs, the lower limit of the content measurement of some elements can be extended to 0.001%.

2.2 Types of Measurable Substances

2.2.1 Silicate and Aluminosilicate:

Ceramic raw materials (including glazes) and finished products, refractory material raw materials and finished products, glass raw materials (including microcrystalline glass) and finished products, cement main raw materials and finished products, and other inorganic non-metallic materials.

2.2.2 The following non-ferrous metal minerals and alloys and main components of chemical raw materials can be determined:

Chromium salt products, V2O5 products, MnO products, NiO products, titanium powder, phosphate, cobalt oxide, zinc oxide, boric acid, borax, barium carbonate, water glass, sodium humate, red lead, iron oxide, molybdenum trioxide, molybdate, molybdenum ore, ferro-molybdenum alloy, molybdenum-nickel alloy, nickel-cobalt-copper alloy, etc.

2.3 Sampling Channels: 7

2.4 Measurement Channels: 6.

2.5 Measurement Stability: The reading changes ±2 digits within 5 minutes.

2.6 Test Repeatability: The reading of the same sample solution in 20 repeated measurements is ±1*

2.7 Detection Speed:

From the beginning of weighing, it takes about 2 hours to complete the determination of SiO2, Al2O3, Fe2O3, TiO2, K2O, Na2O, CaO, and MgO in 4 conventional samples. The determination of other elements can be completed within 4-6 hours.

2.8 Number of continuously measured samples: More than 10.

3. DHF84 Multi-element Rapid Analyzer, Instrument Operating Conditions:

Power Supply 220V 50Hz

Total Power 1KW

Ambient Temperature 25±5℃

Relative Humidity ≤85%

4. DHF84 Multi-element Rapid Analyzer, Instrument Configuration:

DHF84 analyzer host: 1 unit;

Data processing system: 1 set (1 computer, 1 printer, 1 software);

Flame photometer: 1 set;

30ml silver crucible: 4 sets;

Ultrasonic cleaner: 1 unit;

Standard stock solution: 1 set (limited to conventional 8 elements).

Relevant Specifications

Relevant Specifications

Inquire

If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!

Submit