Product

Thermal Conductivity Tester for Thermal Insulation Materials


The Xiangke DRPL-III Thermal Conductivity Tester (Guard Heat Flow Meter Method) is suitable for testing the thermal conductivity of low thermal conductivity materials such as insulation materials and refractory materials. With an optional sample frame, it can also test powder materials. It is widely used in colleges and universities, research institutes, quality inspection departments, and factories.

零售价

¥ 55000

市场价

¥ 55000

库存

7

  • Specifications
    • DRPL-III-300 100℃ DRPL-III-300 Thermal conductivity meter (flat plate heat flow meter method)
    • DRPL-III-250 DRPL-III-250 Thermal conductivity meter (flat plate heat flow meter method)

You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
Quantity
-
+

库存剩余

7

隐藏域元素占位

  • 产品描述
    • Commodity name: Thermal Conductivity Tester for Thermal Insulation Materials
    • Model: Hunan Xiangke DRPL-III

    The Xiangke DRPL-III Thermal Conductivity Tester (Guard Heat Flow Meter Method) is suitable for testing the thermal conductivity of low thermal conductivity materials such as insulation materials and refractory materials. With an optional sample frame, it can also test powder materials. It is widely used in colleges and universities, research institutes, quality inspection departments, and factories.

    Xiangke DRPL-III Thermal Conductivity Meter (Guarded Hot Plate Method)

    I. Xiangke DRPL-III Thermal Conductivity Tester for Insulating Materials (Guarded Hot Plate Method) Overview

    This instrument uses the popular hot plate method to detect thermal conductivity and thermal resistance, and is equipped with a computer to achieve fully automatic detection and generate experimental reports. It is suitable for thermal conductivity testing of low-conductivity materials such as insulation materials and refractory materials. With an additional sample frame, it can also test powder materials. It is widely used in colleges and universities, research institutes, quality inspection departments, and factories and mines.

    This instrument refers to the standards: GB/T10295-2008 (Determination of steady-state thermal resistance and related properties of thermal insulation materials - Hot plate method) and ASTM C518-04 Test method for determining steady-state heat flux and heat transfer properties using a heat flow meter.

    II. Xiangke DRPL-III Thermal Conductivity Tester (Guarded Hot Plate Method) System Composition:

    a) Hot plate heater, high-precision programmable temperature control, fluctuation less than 0.2 degrees, hot plate temperature measurement resolution 0.01℃.

    b) The cold plate uses a constant temperature water bath for temperature control, with a fluctuation of less than 0.05 degrees, and a cold plate temperature measurement resolution of 0.01℃.

    c) The heat flow sensor uses an imported sensor from France.

    III. Xiangke DRPL-III Thermal Conductivity Tester for Insulating Materials Thermal Conductivity Meter (Guarded Hot Plate Method) Main Parameters:

    1. Thermal conductivity test range: 0.002-1 W/MK;

    2. Hot plate temperature range: By changing parameters, detection can be performed in two temperature ranges: room temperature -99.99℃ and room temperature -350.0℃;

    3. Cold plate temperature range: 0-99.99℃;

    4. Sample size: 250×250×(5-40)mm; Effective test size: 120*120mm;

    Or: 300×300×(5-50)mm; Effective test size: 150*150mm;

    Two specifications are available;

    5. Resolution: 0.001wm/k;

    6. Test accuracy: Better than 3%±0.0005 W/MK;

    7. With automatic thickness measurement and reading functions, automatic pressurization and pressure reading functions, electric loading and unloading, adjustable speed, and the pressure of the measured material can be set, and the pressurization device is stable;

    8. The test part uses a transparent plexiglass windproof cover with a side door, allowing you to see the test situation inside the instrument.

    9. Powder materials can be detected;

    10. Pressure measurement range: 0~1000N

    11. Displacement measurement range: 0~50.00mm

    12. Heat transfer area of cold and hot plates: 250×250 (mm).

    13. Adjustable distance between cold and hot plates: 0-50(mm).

    14. Sample test cycle: about 2 hours.

    IV. Xiangke DRPL-III Thermal Conductivity Meter (Guarded Hot Plate Method) Instrument Completeness

    1. DRPL-III Thermal Conductivity Tester main unit 1 set;

    2. Test software (including communication interface) 1 set;

    3. Constant temperature water bath and its controller 1 set;

    4. Computer printer 1 set (as per contract configuration).

Thermal Conductivity Tester for Thermal Insulation Materials


Model:

Hunan Xiangke DRPL-III

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


The Xiangke DRPL-III Thermal Conductivity Tester (Guard Heat Flow Meter Method) is suitable for testing the thermal conductivity of low thermal conductivity materials such as insulation materials and refractory materials. With an optional sample frame, it can also test powder materials. It is widely used in colleges and universities, research institutes, quality inspection departments, and factories.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

Xiangke DRPL-III Thermal Conductivity Meter (Guarded Hot Plate Method)

I. Xiangke DRPL-III Thermal Conductivity Tester for Insulating Materials (Guarded Hot Plate Method) Overview

This instrument uses the popular hot plate method to detect thermal conductivity and thermal resistance, and is equipped with a computer to achieve fully automatic detection and generate experimental reports. It is suitable for thermal conductivity testing of low-conductivity materials such as insulation materials and refractory materials. With an additional sample frame, it can also test powder materials. It is widely used in colleges and universities, research institutes, quality inspection departments, and factories and mines.

This instrument refers to the standards: GB/T10295-2008 (Determination of steady-state thermal resistance and related properties of thermal insulation materials - Hot plate method) and ASTM C518-04 Test method for determining steady-state heat flux and heat transfer properties using a heat flow meter.

II. Xiangke DRPL-III Thermal Conductivity Tester (Guarded Hot Plate Method) System Composition:

a) Hot plate heater, high-precision programmable temperature control, fluctuation less than 0.2 degrees, hot plate temperature measurement resolution 0.01℃.

b) The cold plate uses a constant temperature water bath for temperature control, with a fluctuation of less than 0.05 degrees, and a cold plate temperature measurement resolution of 0.01℃.

c) The heat flow sensor uses an imported sensor from France.

III. Xiangke DRPL-III Thermal Conductivity Tester for Insulating Materials Thermal Conductivity Meter (Guarded Hot Plate Method) Main Parameters:

1. Thermal conductivity test range: 0.002-1 W/MK;

2. Hot plate temperature range: By changing parameters, detection can be performed in two temperature ranges: room temperature -99.99℃ and room temperature -350.0℃;

3. Cold plate temperature range: 0-99.99℃;

4. Sample size: 250×250×(5-40)mm; Effective test size: 120*120mm;

Or: 300×300×(5-50)mm; Effective test size: 150*150mm;

Two specifications are available;

5. Resolution: 0.001wm/k;

6. Test accuracy: Better than 3%±0.0005 W/MK;

7. With automatic thickness measurement and reading functions, automatic pressurization and pressure reading functions, electric loading and unloading, adjustable speed, and the pressure of the measured material can be set, and the pressurization device is stable;

8. The test part uses a transparent plexiglass windproof cover with a side door, allowing you to see the test situation inside the instrument.

9. Powder materials can be detected;

10. Pressure measurement range: 0~1000N

11. Displacement measurement range: 0~50.00mm

12. Heat transfer area of cold and hot plates: 250×250 (mm).

13. Adjustable distance between cold and hot plates: 0-50(mm).

14. Sample test cycle: about 2 hours.

IV. Xiangke DRPL-III Thermal Conductivity Meter (Guarded Hot Plate Method) Instrument Completeness

1. DRPL-III Thermal Conductivity Tester main unit 1 set;

2. Test software (including communication interface) 1 set;

3. Constant temperature water bath and its controller 1 set;

4. Computer printer 1 set (as per contract configuration).

Relevant Specifications