Product

Thermal Conductivity Tester (Plate Steady-State Method), Thermal Conductivity Meter


Xiangke DRP-Ⅱ thermal conductivity tester (plate steady-state method) uses the steady-state method to measure the thermal conductivity of different materials. Its design is clear, simple, and the experimental method is typical and practical. Thermal conductivity test range: 0.1~300w/m·k, test materials: silicone rubber, bakelite, aluminum, air, etc.

零售价

¥ 5500

市场价

¥ 5500

库存

10

  • Specifications
    • DRP-II Thermal conductivity tester DRP-II Thermal conductivity meter for teaching purposes

You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
Quantity
-
+

库存剩余

10

隐藏域元素占位

  • 产品描述
    • Commodity name: Thermal Conductivity Tester (Plate Steady-State Method), Thermal Conductivity Meter
    • Model: Hunan Science and Technology DRP-Ⅱ

    Xiangke DRP-Ⅱ thermal conductivity tester (plate steady-state method) uses the steady-state method to measure the thermal conductivity of different materials. Its design is clear, simple, and the experimental method is typical and practical. Thermal conductivity test range: 0.1~300w/m·k, test materials: silicone rubber, bakelite, aluminum, air, etc.

    Xiangke DRP-Ⅱ Thermal Conductivity Tester (Plate Steady-State Method), Thermal Conductivity Meter Overview: 
    Thermal conductivity is a physical quantity that reflects the thermal conductivity of a material. It is not only the basis for evaluating the thermal properties of a material, but also a design basis for the application of the material. This parameter is involved in engineering practices such as heater, radiator, heat transfer pipe design, and house design. Because the thermal conductivity of a material not only changes with temperature and pressure, but also the impurity content and structural changes of the material will significantly affect the value of thermal conductivity, the thermal conductivity of materials is often determined by experimental methods in scientific experiments and engineering technology. 
    This tester consists of a heater, a digital thermometer, and a digital timer (using an integrated design). 
    Xiangke DRP-Ⅱ Thermal Conductivity Tester (Plate Steady-State Method), Thermal Conductivity Meter Technical Parameters: 
    1. Power supply: AC 220V; 50HZ 
    2. Heat source: Heated copper block, using 36V safety voltage heating 
    3. Test materials: Silicone rubber, Bakelite, aluminum, air, etc. 
    4. Measurement temperature range: Room temperature ~ 110℃, accuracy ±1℃; 
    5. Timing section: Range 0~9999.9s; Resolution 0.1s; 
    6. Thermal conductivity measurement accuracy: ≤10%, 
    7. Sample size: Φ130×(1-100)mm,

    8. Thermal conductivity test range: 0.1~100w/m·k,

    Instrument configuration: Includes 1 DRP-II test host, 2 thermocouples, 1 aluminum sample, 1 insulation bucket, 1 baffle plate, and 1 thermal grease.

    Manufacturer supply, for rough testing, experimental thermal conductivity meter, *, welcome to inquire!

Thermal Conductivity Tester (Plate Steady-State Method), Thermal Conductivity Meter


Model:

Hunan Science and Technology DRP-Ⅱ

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


Xiangke DRP-Ⅱ thermal conductivity tester (plate steady-state method) uses the steady-state method to measure the thermal conductivity of different materials. Its design is clear, simple, and the experimental method is typical and practical. Thermal conductivity test range: 0.1~300w/m·k, test materials: silicone rubber, bakelite, aluminum, air, etc.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

Xiangke DRP-Ⅱ Thermal Conductivity Tester (Plate Steady-State Method), Thermal Conductivity Meter Overview: 
Thermal conductivity is a physical quantity that reflects the thermal conductivity of a material. It is not only the basis for evaluating the thermal properties of a material, but also a design basis for the application of the material. This parameter is involved in engineering practices such as heater, radiator, heat transfer pipe design, and house design. Because the thermal conductivity of a material not only changes with temperature and pressure, but also the impurity content and structural changes of the material will significantly affect the value of thermal conductivity, the thermal conductivity of materials is often determined by experimental methods in scientific experiments and engineering technology. 
This tester consists of a heater, a digital thermometer, and a digital timer (using an integrated design). 
Xiangke DRP-Ⅱ Thermal Conductivity Tester (Plate Steady-State Method), Thermal Conductivity Meter Technical Parameters: 
1. Power supply: AC 220V; 50HZ 
2. Heat source: Heated copper block, using 36V safety voltage heating 
3. Test materials: Silicone rubber, Bakelite, aluminum, air, etc. 
4. Measurement temperature range: Room temperature ~ 110℃, accuracy ±1℃; 
5. Timing section: Range 0~9999.9s; Resolution 0.1s; 
6. Thermal conductivity measurement accuracy: ≤10%, 
7. Sample size: Φ130×(1-100)mm,

8. Thermal conductivity test range: 0.1~100w/m·k,

Instrument configuration: Includes 1 DRP-II test host, 2 thermocouples, 1 aluminum sample, 1 insulation bucket, 1 baffle plate, and 1 thermal grease.