Product

Fully Automatic Specific Heat Capacity Tester


The BRR-3C fully automatic specific heat capacity tester is suitable for high-accuracy measurement of specific heat capacity at room temperature to 100℃, and meets the requirements of the GJB 330A-2000 standard. All measurements and controls of this instrument are computer-controlled, reducing human error and improving testing accuracy.

零售价

¥ 65000

市场价

¥ 65000

库存

11

  • Specifications
    • BRR-3C(RT-100℃) integrated BRR-3C(RT-100℃) integrated Specific heat capacity tester
    • BRR-3C(RT-150℃) integrated BRR-3C(RT-150℃) integrated Specific heat capacity tester
    • BRR-3C(RT-100℃)  split-type BRR-3C(RT-100℃) split-type Specific heat capacity tester
    • BRR-3C(RT-150℃)  split-type BRR-3C(RT-150℃) split-type Specific heat capacity tester

You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
Quantity
-
+

库存剩余

11

隐藏域元素占位

  • 产品描述
    • Commodity name: Fully Automatic Specific Heat Capacity Tester
    • Model: BRR-3C

    The BRR-3C fully automatic specific heat capacity tester is suitable for high-accuracy measurement of specific heat capacity at room temperature to 100℃, and meets the requirements of the GJB 330A-2000 standard. All measurements and controls of this instrument are computer-controlled, reducing human error and improving testing accuracy.

    Xiangtan Xiangke BRR-3C Automatic Specific Heat Capacity Tester (Room Temperature)

    The BRR-3C instrument is suitable for high-accuracy measurement of specific heat capacity at room temperature to 100℃, meeting the requirements of the GJB 330A-2000 standard. All measurements and controls of this instrument are computer-controlled, reducing human error and improving testing accuracy.

    Xiangtan Xiangke BRR-3C Automatic Specific Heat Capacity Tester Main Technical Parameters:

    Instrument Model Specifications

    BRR-3C (Room temperature—100℃) or customized to room temperature—150℃ as required

    1. Specific Heat Capacity Range

    0.05-5 (kj/kg*k)

    2. Testing Accuracy

    Solid ≤2%±0.008; Powder, Liquid ≤3%±0.008

    3. Testing Temperature Range

    Room temperature—100℃ or customized to room temperature—150℃ as required

    4. Sample Requirements

    Solid sample size, φ20*80 (mm); Powder, liquid sample volume, about 25 (cm3).

    5. Calorimetric Resolution

    0.001℃

    6. Calorimeter

    Calorimeter power supply: Voltage 0-24V, resolution 1mV; Current 0-1A, resolution 0.01mA.

    7. Atmosphere Environment

    Normal pressure

    8. Experimental Method

    Adiabatic method

    9. Power Supply

    220V/50Hz, power consumption less than 1KW

    10. Measurement and Control Method

    Fully automatic computer testing, data processing, and can generate test reports for printing output.

    11. Instrument Configuration

    Split type: Includes one BRR-3C specific heat capacity instrument host, one software, one set of communication interface and data cable, one high-precision constant temperature water bath, one desktop computer (as per contract configuration).

    Integrated type: Includes one BRR-3C specific heat capacity instrument host (including touch screen industrial control computer), one software, one set of communication interface and data cable, one high-precision constant temperature water bath.

    Two appearance styles are available:

    Xiangtan Instruments Co., Ltd. After-sales Service Letter of Commitment

    We guarantee to provide service according to the following terms:

    1. We will provide on-site installation, debugging, and operator training, and will provide long-term and excellent after-sales service according to the characteristics of this procurement project.

    2. We provide a one-year free warranty from the date of acceptance (excluding consumables), free software upgrades, and all free repair services during the warranty period, as well as lifetime after-sales service. After the warranty period, we will provide lifetime paid repair services, technical support, and regular inspections.

    3. If a product malfunction occurs, we will respond within 4 hours of receiving the fault report and propose feasible solutions within 24 hours; during the warranty period, if the equipment malfunctions due to its own quality problems, we will be responsible for free repair and replacement of parts.

    4. During the warranty period, we will replace damaged parts due to normal use free of charge, and provide maintenance parts at cost after the warranty period.

    5. We will provide telephone guidance and remote network technical support to solve problems for customers in a high-quality and efficient manner.

    6. We will provide long-term excellent technical support and preferential supply of spare parts.

    7. We will provide a professional after-sales service team composed of senior engineers and project managers with many years of experience to provide high-quality after-sales service.

Fully Automatic Specific Heat Capacity Tester


Model:

BRR-3C

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


The BRR-3C fully automatic specific heat capacity tester is suitable for high-accuracy measurement of specific heat capacity at room temperature to 100℃, and meets the requirements of the GJB 330A-2000 standard. All measurements and controls of this instrument are computer-controlled, reducing human error and improving testing accuracy.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

Xiangtan Xiangke BRR-3C Automatic Specific Heat Capacity Tester (Room Temperature)

The BRR-3C instrument is suitable for high-accuracy measurement of specific heat capacity at room temperature to 100℃, meeting the requirements of the GJB 330A-2000 standard. All measurements and controls of this instrument are computer-controlled, reducing human error and improving testing accuracy.

Xiangtan Xiangke BRR-3C Automatic Specific Heat Capacity Tester Main Technical Parameters:

Instrument Model Specifications

BRR-3C (Room temperature—100℃) or customized to room temperature—150℃ as required

1. Specific Heat Capacity Range

0.05-5 (kj/kg*k)

2. Testing Accuracy

Solid ≤2%±0.008; Powder, Liquid ≤3%±0.008

3. Testing Temperature Range

Room temperature—100℃ or customized to room temperature—150℃ as required

4. Sample Requirements

Solid sample size, φ20*80 (mm); Powder, liquid sample volume, about 25 (cm3).

5. Calorimetric Resolution

0.001℃

6. Calorimeter

Calorimeter power supply: Voltage 0-24V, resolution 1mV; Current 0-1A, resolution 0.01mA.

7. Atmosphere Environment

Normal pressure

8. Experimental Method

Adiabatic method

9. Power Supply

220V/50Hz, power consumption less than 1KW

10. Measurement and Control Method

Fully automatic computer testing, data processing, and can generate test reports for printing output.

11. Instrument Configuration

Split type: Includes one BRR-3C specific heat capacity instrument host, one software, one set of communication interface and data cable, one high-precision constant temperature water bath, one desktop computer (as per contract configuration).

Integrated type: Includes one BRR-3C specific heat capacity instrument host (including touch screen industrial control computer), one software, one set of communication interface and data cable, one high-precision constant temperature water bath.

Two appearance styles are available:

Xiangtan Instruments Co., Ltd. After-sales Service Letter of Commitment

We guarantee to provide service according to the following terms:

1. We will provide on-site installation, debugging, and operator training, and will provide long-term and excellent after-sales service according to the characteristics of this procurement project.

2. We provide a one-year free warranty from the date of acceptance (excluding consumables), free software upgrades, and all free repair services during the warranty period, as well as lifetime after-sales service. After the warranty period, we will provide lifetime paid repair services, technical support, and regular inspections.

3. If a product malfunction occurs, we will respond within 4 hours of receiving the fault report and propose feasible solutions within 24 hours; during the warranty period, if the equipment malfunctions due to its own quality problems, we will be responsible for free repair and replacement of parts.

4. During the warranty period, we will replace damaged parts due to normal use free of charge, and provide maintenance parts at cost after the warranty period.

5. We will provide telephone guidance and remote network technical support to solve problems for customers in a high-quality and efficient manner.

6. We will provide long-term excellent technical support and preferential supply of spare parts.

7. We will provide a professional after-sales service team composed of senior engineers and project managers with many years of experience to provide high-quality after-sales service.

Relevant Specifications

Relevant Specifications

Inquire

If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!

Submit