Fully Automatic Specific Heat Capacity Tester
零售价
¥ 88000
市场价
¥ 88000
库存
12
-
Specifications
-
BRR-3C(RT-100℃) integrated Specific heat capacity tester
-
BRR-3C(RT-150℃) integrated Specific heat capacity tester
-
BRR-3A(200—1300℃)Specific heat capacity tester
-
BRR-3A(400—1550℃)Specific heat capacity tester
-
BRR-3B(100—800℃)Specific heat capacity tester
-
BRR-3D(-40—100℃)Specific heat capacity tester
-
You can send us an email:xtyqyb@163.com
Inquire库存剩余
12
隐藏域元素占位
- 产品描述
-
- Commodity name: Fully Automatic Specific Heat Capacity Tester
- Model: Xiangke BRR-3 series
Xiangtan Xiangke BRR-3 series fully automatic specific heat capacity tester, specific heat capacity meter is used for high-accuracy measurement of specific heat capacity at different temperatures, and meets the requirements of GJB 330A-2000 standard. All measurements and controls of this instrument are computer-controlled, reducing human error and improving testing accuracy.
Xiangtan Xiangke BRR-3 series Fully automatic specific heat capacity tester Specific heat capacity measuring instrument
The BRR-3 series specific heat capacity tester is used for high-accuracy measurement of specific heat capacity at different temperatures, and meets the requirements of the GJB 330A-2000 standard for testing the specific heat capacity of solid materials. All measurements and controls of this instrument are computer-controlled, reducing human error and improving testing accuracy.
Xiangtan Xiangke BRR-3 series Fully automatic specific heat capacity tester Main technical parameters:
Instrument model specifications
BRR-3A (high temperature)
BRR-3B (medium temperature)
BRR-3C (room temperature)
BRR-3D (low temperature)
1. Specific heat capacity range
0.05-5 (kj/kg*k)
0.05-5 (kj/kg*k)
0.05-5 (kj/kg*k)
0.05-5 (kj/kg*k)
2. Testing accuracy
Solid ≤1%±0.002; Powder ≤2%±0.002
Solid ≤1%±0.002; Powder ≤2%±0.002
Solid ≤2%±0.008; Powder, liquid ≤3%±0.008
Granular, powder ≤1%±0.002
3. Test temperature range
200—1300℃ or 400—1550℃
100—800℃
Room temperature—100℃
-40—100℃
4. Sample requirements
Solid sample size, (φ10—φ14) × (20—40) mm; Powder about 6 (cm3)
Solid sample size, (φ16—φ20) × (30—50) mm; Powder about 15 (cm3)
Solid sample size, φ20*80 (mm); Powder, liquid sample volume, about 25 (cm3).
Granular, powder sample volume: about 55 (cm3)
5. Calorimetric resolution
0.001℃
0.001℃
0.001℃
0.001℃
6. Calorimeter
Calorimeter heat capacity about 1500J/K, temperature resolution 0.001℃
Calorimeter heat capacity about 1000J/K, temperature resolution 0.001℃
Calorimeter power supply: voltage 0-24V, resolution 1mV; current 0-1A, resolution 0.01mA.
Calorimeter power supply: voltage 0-24V, resolution 1mV; current 0-1A, resolution 0.01mA.
7. Atmosphere environment
Sample oxidation protection: Argon
Sample oxidation protection: Argon
Normal pressure
Vacuum degree: -0.095MPa
8. Experimental method
Mixing method
Mixing method
Adiabatic method
Adiabatic method
9. Power supply
1300℃ specification 220V/50Hz, W≤6KW.
1550℃ specification 380V/50Hz, W≤8KW.
220V/50Hz, power consumption less than 3KW
220V/50Hz, power consumption less than 1KW
220V/50Hz, power consumption less than 1KW
10. Instrument configuration
Includes one BRR-3A high-temperature specific heat capacity tester host, one set of software, one set of communication interface and data cable, one high-precision constant temperature water bath, and one brand desktop computer (configured according to the contract).
Includes one BRR-3B medium-temperature specific heat capacity tester host, one set of software, one set of communication interface and data cable, one high-precision constant temperature water bath, and one brand desktop computer (configured according to the contract).
Includes one BRR-3C room-temperature specific heat capacity tester host, one set of software, one set of communication interface and data cable, one high-precision constant temperature water bath, and one brand desktop computer (configured according to the contract).
Includes one BRR-3D low-temperature specific heat capacity tester host, one set of software, one set of communication interface and data cable, one high-precision constant temperature water bath, one vacuum pump, and one brand desktop computer (configured according to the contract).
11. Measurement and control method
Fully automatic computer testing, data processing, and can generate test reports for printing output.

Fully Automatic Specific Heat Capacity Tester
Model:
Xiangke BRR-3 series
Specifications:
Specifications:
这里是占位文字
Gross weight (KG):
Xiangtan Xiangke BRR-3 series fully automatic specific heat capacity tester, specific heat capacity meter is used for high-accuracy measurement of specific heat capacity at different temperatures, and meets the requirements of GJB 330A-2000 standard. All measurements and controls of this instrument are computer-controlled, reducing human error and improving testing accuracy.
Category:
You can send us an email:xtyqyb@163.com
InquireProduct Details
Xiangtan Xiangke BRR-3 series Fully automatic specific heat capacity tester Specific heat capacity measuring instrument
The BRR-3 series specific heat capacity tester is used for high-accuracy measurement of specific heat capacity at different temperatures, and meets the requirements of the GJB 330A-2000 standard for testing the specific heat capacity of solid materials. All measurements and controls of this instrument are computer-controlled, reducing human error and improving testing accuracy.
Xiangtan Xiangke BRR-3 series Fully automatic specific heat capacity tester Main technical parameters:
Instrument model specifications | BRR-3A (high temperature) | BRR-3B (medium temperature) | BRR-3C (room temperature) | BRR-3D (low temperature) |
1. Specific heat capacity range | 0.05-5 (kj/kg*k) | 0.05-5 (kj/kg*k) | 0.05-5 (kj/kg*k) | 0.05-5 (kj/kg*k) |
2. Testing accuracy | Solid ≤1%±0.002; Powder ≤2%±0.002 | Solid ≤1%±0.002; Powder ≤2%±0.002 | Solid ≤2%±0.008; Powder, liquid ≤3%±0.008 | Granular, powder ≤1%±0.002 |
3. Test temperature range | 200—1300℃ or 400—1550℃ | 100—800℃ | Room temperature—100℃ | -40—100℃ |
4. Sample requirements | Solid sample size, (φ10—φ14) × (20—40) mm; Powder about 6 (cm3) | Solid sample size, (φ16—φ20) × (30—50) mm; Powder about 15 (cm3) | Solid sample size, φ20*80 (mm); Powder, liquid sample volume, about 25 (cm3). | Granular, powder sample volume: about 55 (cm3) |
5. Calorimetric resolution | 0.001℃ | 0.001℃ | 0.001℃ | 0.001℃ |
6. Calorimeter | Calorimeter heat capacity about 1500J/K, temperature resolution 0.001℃ | Calorimeter heat capacity about 1000J/K, temperature resolution 0.001℃ | Calorimeter power supply: voltage 0-24V, resolution 1mV; current 0-1A, resolution 0.01mA. | Calorimeter power supply: voltage 0-24V, resolution 1mV; current 0-1A, resolution 0.01mA. |
7. Atmosphere environment | Sample oxidation protection: Argon | Sample oxidation protection: Argon | Normal pressure | Vacuum degree: -0.095MPa |
8. Experimental method | Mixing method | Mixing method | Adiabatic method | Adiabatic method |
9. Power supply | 1300℃ specification 220V/50Hz, W≤6KW. 1550℃ specification 380V/50Hz, W≤8KW. | 220V/50Hz, power consumption less than 3KW | 220V/50Hz, power consumption less than 1KW | 220V/50Hz, power consumption less than 1KW |
10. Instrument configuration | Includes one BRR-3A high-temperature specific heat capacity tester host, one set of software, one set of communication interface and data cable, one high-precision constant temperature water bath, and one brand desktop computer (configured according to the contract). | Includes one BRR-3B medium-temperature specific heat capacity tester host, one set of software, one set of communication interface and data cable, one high-precision constant temperature water bath, and one brand desktop computer (configured according to the contract). | Includes one BRR-3C room-temperature specific heat capacity tester host, one set of software, one set of communication interface and data cable, one high-precision constant temperature water bath, and one brand desktop computer (configured according to the contract). | Includes one BRR-3D low-temperature specific heat capacity tester host, one set of software, one set of communication interface and data cable, one high-precision constant temperature water bath, one vacuum pump, and one brand desktop computer (configured according to the contract). |
11. Measurement and control method | Fully automatic computer testing, data processing, and can generate test reports for printing output. | |||

Relevant Specifications
Relevant Specifications
Recommend
Recommend
Inquire
If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!