Thermal Insulation Performance Tester
零售价
¥ 55000
市场价
¥ 55000
库存
7
-
Specifications
-
RBC-II-30KN(120*120mm,1000℃)Thermal Insulation Performance Measurement Instrument
-
RBC-II-10KN(100*100mm,1000℃)Thermal Insulation Performance Measurement Instrument
-
You can send us an email:xtyqyb@163.com
Inquire库存剩余
7
隐藏域元素占位
- 产品描述
-
- Commodity name: Thermal Insulation Performance Tester
- Model: RBC-II-30KN
The thermal insulation performance tester (material cold surface temperature tester) is suitable for testing the thermal insulation performance of thermal insulation materials. The instrument measures the temperature difference between the two sides of the sample as a function of time within the temperature range of room temperature ~ 1000 ℃. The hot surface achieves a steady-state heat source, with temperature control from room temperature to 1000 ℃ and automatic acquisition of temperature and time data. The cold surface achieves precise testing of the back temperature of the sample and automatic acquisition of temperature and time data. The equipment can perform tests under an electric load of 0~30KN pressure.
Xiangke RBC-II-30KN Thermal Insulation Performance Tester (Material Cold Surface Temperature Tester) (120*120mm, 1000℃) Introduction:
This equipment is suitable for testing the thermal insulation performance of thermal insulation materials. The instrument measures the temperature difference between the two sides of the sample in the temperature range of room temperature to 1000℃, with a steady-state heat source on the hot side. The temperature is controlled from room temperature to 1000℃, and temperature and time data are automatically collected. The cold side achieves precise testing of the sample back temperature and automatically collects temperature and time data. The equipment can achieve electric loading of 0~30KN pressure, ensuring close contact between the sample and the temperature measuring end. It is also equipped with a high-precision displacement sensor to measure the thickness change of the sample under different pressures.
Thermal Insulation Performance Tester Main Technical Parameters:
1. Sample stage size: 120*120mm, sample thickness range: 0.5mm~60mm. (Note: Other sizes can be customized according to customer requirements)
2. Maximum temperature of the hot side: 1000℃, heating holding time: more than 20 minutes. Temperature control accuracy: ±1℃.
3. 1 temperature measuring point on the hot side. The hot side material can withstand 1000℃ for a long time.
4. 2 temperature measuring points on the cold side. The cold side contact end uses heat-resistant stainless steel. Note: Additional temperature measuring points can be added by adding external temperature measuring wires for multi-layer testing.
5. The instrument is equipped with an automatic loading device and is connected to a computer for automatic control. The pressure is adjustable, with specifications such as 0~10KN, 0~20KN, and 0~30KN available. Pressure control accuracy: ±1%.
6. Equipped with a high-precision displacement sensor to measure the thickness change of the sample under different pressures, with a resolution of 1µm.
7. Pressure, temperature, and sample thickness are displayed on the digital instrument and can be controlled by a computer for data processing and report generation. Data can be transferred out using a U disk and printed. The temperature instrument sampling frequency can be selected as 0.1s, 0.5s, and 1s; the number of temperature instrument sampling channels ≥8.
8. High-temperature protection device: High-temperature anti-scalding protection measures - protective cover added to the sample test.
9. The sample can be placed after the heating stage is heated to the required temperature, manual sample loading.
10. Main accessory specifications: Pressure sensor (can be selected according to customer requirements), thermocouple: K type, intelligent temperature control instrument: Xiamen Yudian AI series, high-precision displacement sensor: WYD series.
11. The instrument performs automatic computer testing and data processing, and saves curves and test data.
12. Voltage: 220V, 50HZ, Power: 2KW.
Configuration List:
Serial Number
Name
Brand and Model
Quantity
Remarks
1
Hot Plate Temperature Difference Testing Device Host
Xiangke
RBC-II-30KN
1 set
120*120mm, 1000℃
2
Testing Software
Xiangke RBC-II-30KN
1 copy
3
Data Cable
Xiangke RBC-II-30KN
1 set
4
Silicon Carbide Rod
1 set
Installed on the host
5
Temperature Measuring Thermocouple
K type
3
Installed on the host
6
Computer
1 set
As per contract configuration
Thermal Insulation Performance Tester
Model:
RBC-II-30KN
Specifications:
Specifications:
这里是占位文字
Gross weight (KG):
The thermal insulation performance tester (material cold surface temperature tester) is suitable for testing the thermal insulation performance of thermal insulation materials. The instrument measures the temperature difference between the two sides of the sample as a function of time within the temperature range of room temperature ~ 1000 ℃. The hot surface achieves a steady-state heat source, with temperature control from room temperature to 1000 ℃ and automatic acquisition of temperature and time data. The cold surface achieves precise testing of the back temperature of the sample and automatic acquisition of temperature and time data. The equipment can perform tests under an electric load of 0~30KN pressure.
Category:
You can send us an email:xtyqyb@163.com
InquireProduct Details
Xiangke RBC-II-30KN Thermal Insulation Performance Tester (Material Cold Surface Temperature Tester) (120*120mm, 1000℃) Introduction:
This equipment is suitable for testing the thermal insulation performance of thermal insulation materials. The instrument measures the temperature difference between the two sides of the sample in the temperature range of room temperature to 1000℃, with a steady-state heat source on the hot side. The temperature is controlled from room temperature to 1000℃, and temperature and time data are automatically collected. The cold side achieves precise testing of the sample back temperature and automatically collects temperature and time data. The equipment can achieve electric loading of 0~30KN pressure, ensuring close contact between the sample and the temperature measuring end. It is also equipped with a high-precision displacement sensor to measure the thickness change of the sample under different pressures.
Thermal Insulation Performance Tester Main Technical Parameters:
1. Sample stage size: 120*120mm, sample thickness range: 0.5mm~60mm. (Note: Other sizes can be customized according to customer requirements)
2. Maximum temperature of the hot side: 1000℃, heating holding time: more than 20 minutes. Temperature control accuracy: ±1℃.
3. 1 temperature measuring point on the hot side. The hot side material can withstand 1000℃ for a long time.
4. 2 temperature measuring points on the cold side. The cold side contact end uses heat-resistant stainless steel. Note: Additional temperature measuring points can be added by adding external temperature measuring wires for multi-layer testing.
5. The instrument is equipped with an automatic loading device and is connected to a computer for automatic control. The pressure is adjustable, with specifications such as 0~10KN, 0~20KN, and 0~30KN available. Pressure control accuracy: ±1%.
6. Equipped with a high-precision displacement sensor to measure the thickness change of the sample under different pressures, with a resolution of 1µm.
7. Pressure, temperature, and sample thickness are displayed on the digital instrument and can be controlled by a computer for data processing and report generation. Data can be transferred out using a U disk and printed. The temperature instrument sampling frequency can be selected as 0.1s, 0.5s, and 1s; the number of temperature instrument sampling channels ≥8.
8. High-temperature protection device: High-temperature anti-scalding protection measures - protective cover added to the sample test.
9. The sample can be placed after the heating stage is heated to the required temperature, manual sample loading.
10. Main accessory specifications: Pressure sensor (can be selected according to customer requirements), thermocouple: K type, intelligent temperature control instrument: Xiamen Yudian AI series, high-precision displacement sensor: WYD series.
11. The instrument performs automatic computer testing and data processing, and saves curves and test data.
12. Voltage: 220V, 50HZ, Power: 2KW.
Configuration List:
Serial Number | Name | Brand and Model | Quantity | Remarks |
1 | Hot Plate Temperature Difference Testing Device Host | Xiangke RBC-II-30KN | 1 set |
120*120mm, 1000℃ |
2 | Testing Software |
Xiangke RBC-II-30KN | 1 copy | |
3 | Data Cable |
Xiangke RBC-II-30KN | 1 set | |
4 | Silicon Carbide Rod | 1 set | Installed on the host | |
5 | Temperature Measuring Thermocouple | K type | 3 | Installed on the host |
6 | Computer | 1 set | As per contract configuration |
Relevant Specifications
Relevant Specifications
Recommend
Recommend
Inquire
If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!