Product

Ceramic Tile Wet Expansion Meter, Ceramic Testing Instrument


PY ceramic tile wet expansion meter, ceramic testing instrument meets GB/T3810.10-2016, suitable for the determination of wet heat expansion of ceramic tiles.

零售价

¥ 12800

市场价

¥ 12800

库存

12

  • Specifications
    • SPY  Split type,Ceramic Tile Wet Expansion Meter SPY Split type,Ceramic Tile Wet Expansion Meter
    • SPY Integrated type,Ceramic Tile Wet Expansion Meter SPY Integrated type,Ceramic Tile Wet Expansion Meter

You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
Quantity
-
+

库存剩余

12

隐藏域元素占位

  • 产品描述
    • Commodity name: Ceramic Tile Wet Expansion Meter, Ceramic Testing Instrument
    • Model: SPY

    PY ceramic tile wet expansion meter, ceramic testing instrument meets GB/T3810.10-2016, suitable for the determination of wet heat expansion of ceramic tiles.

    SPY Ceramic Tile Wet Expansion Meter, Ceramic Testing Instrument (Split Type)

    This instrument meets the requirements of GB/T3810.10-2016 and ISO 10545.10-1995 "Ceramic Tile Test Methods Part 10: Determination of Wet Expansion", and is suitable for the determination of wet heat expansion of ceramic tiles. 
    Main Technical Parameters: 
    1. Maximum operating temperature: 800℃, 
    2. Deformation measurement range: ±5mm, 
    3. Sensitivity: ≤1um, 
    4. Temperature control accuracy: ±5℃, 
    5. Sample size: Length × Width = 100 × 50㎜, 
    6. Power supply: 220V, 5KW

    Instrument Composition:

    One SX2-4-10 electric furnace (maximum temperature 1000℃, furnace chamber size 300*300*120mm, PID intelligent program temperature control);

    One water boiler; 
    One micrometer mechanism;

    One dial indicator;

    One standard rod.

    SPY Ceramic Tile Wet Expansion Meter, Ceramic Testing Instrument (Integrated Type)

    This instrument meets the requirements of GB/T3810.10-2016 and ISO 10545.10-1995 "Ceramic Tile Test Methods Part 10: Determination of Wet Expansion", and is suitable for the determination of wet heat expansion of ceramic tiles. 
    Main Technical Parameters: 
    1. Maximum operating temperature: 800℃, 
    2. Deformation measurement range: ±5mm, 
    3. Sensitivity: ≤1um, 
    4. Temperature control accuracy: ±5℃, 
    5. Sample size: Length × Width = 100 × 50㎜, 
    6. Power supply: 220V, 5KW

    Instrument Composition:

    One SPY integrated wet expansion meter;

    One micrometer mechanism;

    One dial indicator;

    One standard rod.

Ceramic Tile Wet Expansion Meter, Ceramic Testing Instrument


Model:

SPY

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


PY ceramic tile wet expansion meter, ceramic testing instrument meets GB/T3810.10-2016, suitable for the determination of wet heat expansion of ceramic tiles.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

SPY Ceramic Tile Wet Expansion Meter, Ceramic Testing Instrument (Split Type)

This instrument meets the requirements of GB/T3810.10-2016 and ISO 10545.10-1995 "Ceramic Tile Test Methods Part 10: Determination of Wet Expansion", and is suitable for the determination of wet heat expansion of ceramic tiles. 
Main Technical Parameters: 
1. Maximum operating temperature: 800℃, 
2. Deformation measurement range: ±5mm, 
3. Sensitivity: ≤1um, 
4. Temperature control accuracy: ±5℃, 
5. Sample size: Length × Width = 100 × 50㎜, 
6. Power supply: 220V, 5KW

Instrument Composition:

One SX2-4-10 electric furnace (maximum temperature 1000℃, furnace chamber size 300*300*120mm, PID intelligent program temperature control);

One water boiler; 
One micrometer mechanism;

One dial indicator;

One standard rod.

SPY Ceramic Tile Wet Expansion Meter, Ceramic Testing Instrument (Integrated Type)

This instrument meets the requirements of GB/T3810.10-2016 and ISO 10545.10-1995 "Ceramic Tile Test Methods Part 10: Determination of Wet Expansion", and is suitable for the determination of wet heat expansion of ceramic tiles. 
Main Technical Parameters: 
1. Maximum operating temperature: 800℃, 
2. Deformation measurement range: ±5mm, 
3. Sensitivity: ≤1um, 
4. Temperature control accuracy: ±5℃, 
5. Sample size: Length × Width = 100 × 50㎜, 
6. Power supply: 220V, 5KW

Instrument Composition:

One SPY integrated wet expansion meter;

One micrometer mechanism;

One dial indicator;

One standard rod.