Product

Glass Annealing Point and Strain Point Tester


The Xiangke CJY-I glass annealing point and strain point tester uses the drawing method to test the annealing point and strain point of glass, referring to the standards ASTM C336, SJT11039-1996 Electronic Glass Annealing Point and Strain Point Test Method, and JC/T752-1996 Quartz Glass Annealing Point Test Method.

零售价

市场价

库存

Quantity
-
+

库存剩余

隐藏域元素占位

  • 产品描述
    • Commodity name: Glass Annealing Point and Strain Point Tester
    • Model: Hunan Science and Technology CJY-I

    The Xiangke CJY-I glass annealing point and strain point tester uses the drawing method to test the annealing point and strain point of glass, referring to the standards ASTM C336, SJT11039-1996 Electronic Glass Annealing Point and Strain Point Test Method, and JC/T752-1996 Quartz Glass Annealing Point Test Method.

    Xiangke CJY-I Glass Annealing Point and Strain Point Tester CJY-I Glass Annealing Point Temperature Tester

    This instrument uses the fiber drawing method to test the annealing point and strain point of glass, referring to the standards ASTM C336, SJT11039-1996 Electronic Glass Annealing Point and Strain Point Test Method, and JC/T752-1996 Quartz Glass Annealing Point Test Method;

    Xiangke CJY-I Glass Annealing Point and Strain Point Tester Technical Parameters:

    1. Maximum temperature 1000℃;

    2. Accuracy: less than 1%;

    3. Temperature control: PID control, automatic control;

    4. Temperature error: ±1℃.

    Configuration: Includes one CJY-I electrical controller, one furnace body and observation device, and one K-type thermocouple.

    Related Products:

    Xiangke RHY-I Glass Softening Point Tester (Fiber Drawing Method)

    This instrument uses the fiber drawing method to test the softening point of glass, referring to the standard JC/T751-1996 Quartz Glass Softening Point Test Method (Fiber Drawing Method).

    Technical Parameters:

    1. Test method: Hanging wire method;

    2. Maximum operating temperature: 1000℃;

    3. Accuracy: less than 0.5%;

    RWY-BL Glass Thermal Stability Tester (Water Cooling Method)

    This instrument is used to measure the thermal stability of glass products, meeting the requirements of GB/T10701-2008 and ISO 718:1990 Quartz Glass Thermal Stability Test Method, and can also be used for the thermal stability of other silicate products.

    Main Technical Parameters:

    1. Maximum operating temperature of the furnace body: 400℃;

    2. Temperature control accuracy: ±5℃ (at 300℃);

    3. Water tank temperature control range: 10-50℃;

    4. Temperature control accuracy: ±2℃;

    5. Timer control range: 0~120 minutes.

    4. Timing accuracy: 0.1 seconds

Glass Annealing Point and Strain Point Tester


Model:

Hunan Science and Technology CJY-I

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


The Xiangke CJY-I glass annealing point and strain point tester uses the drawing method to test the annealing point and strain point of glass, referring to the standards ASTM C336, SJT11039-1996 Electronic Glass Annealing Point and Strain Point Test Method, and JC/T752-1996 Quartz Glass Annealing Point Test Method.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

Xiangke CJY-I Glass Annealing Point and Strain Point Tester CJY-I Glass Annealing Point Temperature Tester

This instrument uses the fiber drawing method to test the annealing point and strain point of glass, referring to the standards ASTM C336, SJT11039-1996 Electronic Glass Annealing Point and Strain Point Test Method, and JC/T752-1996 Quartz Glass Annealing Point Test Method;

Xiangke CJY-I Glass Annealing Point and Strain Point Tester Technical Parameters:

1. Maximum temperature 1000℃;

2. Accuracy: less than 1%;

3. Temperature control: PID control, automatic control;

4. Temperature error: ±1℃.

Configuration: Includes one CJY-I electrical controller, one furnace body and observation device, and one K-type thermocouple.

Related Products:

Xiangke RHY-I Glass Softening Point Tester (Fiber Drawing Method)

This instrument uses the fiber drawing method to test the softening point of glass, referring to the standard JC/T751-1996 Quartz Glass Softening Point Test Method (Fiber Drawing Method).

Technical Parameters:

1. Test method: Hanging wire method;

2. Maximum operating temperature: 1000℃;

3. Accuracy: less than 0.5%;

RWY-BL Glass Thermal Stability Tester (Water Cooling Method)

This instrument is used to measure the thermal stability of glass products, meeting the requirements of GB/T10701-2008 and ISO 718:1990 Quartz Glass Thermal Stability Test Method, and can also be used for the thermal stability of other silicate products.

Main Technical Parameters:

1. Maximum operating temperature of the furnace body: 400℃;

2. Temperature control accuracy: ±5℃ (at 300℃);

3. Water tank temperature control range: 10-50℃;

4. Temperature control accuracy: ±2℃;

5. Timer control range: 0~120 minutes.

4. Timing accuracy: 0.1 seconds

Relevant Specifications

Relevant Specifications

Inquire

If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!

Submit