- Commodity name: Instrument for Determining the Thermal Conductivity of Graphite Materials at Medium Temperatures
- Model: Hunan Xiangke DR-SM
Xiangke DR-SM graphite material medium-temperature thermal conductivity tester, graphite thermal conductivity tester meets the requirements of GB/T8722-2008 "Determination method of medium-temperature thermal conductivity of graphite materials", applicable to the determination of thermal conductivity of graphite materials in the range of 100~800℃.
This instrument meets the requirements of GB/T8722-2008 "Determination Method of Thermal Conductivity of Graphite Materials at Medium Temperature", and is suitable for the determination of thermal conductivity of graphite materials in the range of 100~800℃. It features automated computer testing, data processing, and printing of test reports.
Main Technical Parameters
1. Testing temperature range: 100~800℃, using digital instruments for temperature measurement, accuracy better than 0.2 level;
2. Thermal conductivity testing range: 2~80W/M*K;
3. Sample specifications: Φ16×160mm;
4. Sample oxidation protection method: Vacuum + atmosphere,
5. Testing accuracy: Better than ±5%.
Graphite Thermal Conductivity Instrument Components: This instrument consists of an environmental heating system, a cooling system, a vacuum atmosphere system, a sample heating system, a measurement control system, and a computer system.
Graphite Thermal Conductivity Instrument Packing List
1. DR-SM Test Host 1 unit
2. Test Software 1 set
3. Computer (as per contract requirements) 1 set
4. Accompanying Instructions 1 set
5. Qualification Certificate 1 copy
6. DC Regulated Power Supply 1 unit
下一页
Instrument for Determining the Thermal Conductivity of Graphite Materials at Medium Temperatures
Model:
Hunan Xiangke DR-SM
Specifications:
Specifications:
这里是占位文字
Gross weight (KG):
Xiangke DR-SM graphite material medium-temperature thermal conductivity tester, graphite thermal conductivity tester meets the requirements of GB/T8722-2008 "Determination method of medium-temperature thermal conductivity of graphite materials", applicable to the determination of thermal conductivity of graphite materials in the range of 100~800℃.
Category:
You can send us an email:xtyqyb@163.com
InquireProduct Details
This instrument meets the requirements of GB/T8722-2008 "Determination Method of Thermal Conductivity of Graphite Materials at Medium Temperature", and is suitable for the determination of thermal conductivity of graphite materials in the range of 100~800℃. It features automated computer testing, data processing, and printing of test reports.
Main Technical Parameters
1. Testing temperature range: 100~800℃, using digital instruments for temperature measurement, accuracy better than 0.2 level;
2. Thermal conductivity testing range: 2~80W/M*K;
3. Sample specifications: Φ16×160mm;
4. Sample oxidation protection method: Vacuum + atmosphere,
5. Testing accuracy: Better than ±5%.
Graphite Thermal Conductivity Instrument Components: This instrument consists of an environmental heating system, a cooling system, a vacuum atmosphere system, a sample heating system, a measurement control system, and a computer system.
Graphite Thermal Conductivity Instrument Packing List
1. DR-SM Test Host 1 unit
2. Test Software 1 set
3. Computer (as per contract requirements) 1 set
4. Accompanying Instructions 1 set
5. Qualification Certificate 1 copy
6. DC Regulated Power Supply 1 unit