Graphite Carbon Detector
零售价
市场价
重量
库存剩余
隐藏域元素占位
- 产品描述
-
- Commodity name: Graphite Carbon Detector
- Model: DSY-II
The graphite carbon detector uses imported data acquisition and control cards, and is computer-controlled to achieve fully automated testing, calculation, and reporting. A variety of instruments and equipment are available for graphite carbon detection to meet different needs.
Graphite Carbon Detector Introduction:
Name
Model Number
Technical Parameters and Standards
Carbon (Graphite) Permeability Tester
DSY-II
GB/T9973 Test Method for Permeability of Carbon Materials
Carbon (Graphite) Medium Temperature Thermal Conductivity Tester
DR-SM
GB/T8722 Test Method for Medium Temperature Thermal Conductivity of Graphite Materials
1. Room temperature - 1400℃
2. Meets GD8722-2008 requirements
3. With atmosphere protection system
4. Computer automatic testing, controllable heating rate, fully automatic computer testing
5. Data printing output
4. Voltage measurement: Digital voltmeter, accuracy 0.01MV
Carbon (Graphite) Tensile Strength Tester
SLW-I
GB/T8721-2009 Test Method for Tensile Strength of Carbon Materials
Carbon (Graphite) Resistivity Tester
WDT-II
GB/T6717, GB/T 24525-2009, YS/T63.2 Test Method for Resistivity of Carbon Materials
Carbon (Graphite) Thermal Expansion Coefficient Tester
Z RPY-14
00
GB/T3074.4 Test Method for Thermal Expansion Coefficient (CTE) of Graphite Electrodes
1. Maximum furnace temperature: Room temperature - 1400℃
2. Heating rate: 0-20 degrees/min adjustable, computer program temperature control
3. Computer automatically calculates expansion coefficient, volume expansion coefficient, linear expansion, and rapid thermal expansion
4. Automatically calculates and compensates for the compensation coefficient, and manual correction is also possible (online)5. Automatically records, stores, and prints data, prints temperature-expansion coefficient curve, temperature interval freely set, minimum interval 1℃
6. Expansion value measurement range: ±2.5mm
7. Displacement sensor sensitivity 0.1um, measurement accuracy 0.5 um, automatic range correction8. Sample range: Ф6~10×50mm、10×10×50mm
9. Using imported linear bearing drive, realizing frictionless transmission of expansion value, transmission accuracy and repeatability
10. System measurement error: ±0.1-0.5%
11. Power supply voltage: 220V±10%, 2KW12. The instrument is equipped with a standard computer interface, which can be connected to a general-purpose computer. All test operations are completed through the computer interface, which is easy to operate and learn, and provides a complete set of software (equipped with carbon industry detection software)
Carbon (Graphite) Apparent Porosity Tester
DXR-II
GB/T6156, GB/T24529 Test Method for Apparent Porosity of Carbon Materials
Carbon Material True Density Tester
ZMY
GB/T6155-2008 Test Method for True Density and True Porosity of Carbon Materials
Carbon (Graphite) Flexural Strength/Compressive Strength Tester
SGW-II
GB/T3074.1 Test Method for Flexural Strength of Graphite Electrodes GB/T1431 Test Method for Compressive Strength of Carbon Materials
High Temperature Compression and Bending Tester
GKZ
1. Test temperature 1350℃, 1600℃, computer program temperature control
2. Sample size range: 120/20/10 (length/width/height) ×4 (can be customized according to user requirements)
3. Maximum test pressure: 10000N
4. Hydraulic loading system, adjustable speed, pressure, automatic sample feeding
5. Computer data processing
6. Power supply: 380V, 12kw
Dynamic Elastic Modulus Tester
(Carbon Materials)
DTM-II
Instrument reference standard: GB/T3074.2-2008 "Test Method for Elastic Modulus of Graphite Electrodes".
This instrument uses imported data acquisition and control cards, and uses computer control to realize the automation of the entire testing, calculation, and reporting process.
Main Technical Indicators
1. Frequency measurement range: 100Hz~50 kHz
2. Frequency resolution: 0.01Hz
3. Measurement error: <0.5%
Graphite Oxidizability Tester
SG-YH
This equipment meets GB/T3074.3-2008 Test Method for Oxidizability of Graphite Electrodes and is used for the determination of the oxidizability of graphite electrodes.
Main Technical Parameters:
1. Heating furnace operating temperature: Vertical, room temperature to 900℃
2. Using microcomputer program temperature control, temperature control accuracy ±1℃, adjustable heating rate
3. Atmosphere can be introduced into the heating furnace chamber
4. Quartz tube: Outer diameter 64mm, inner diameter 56mm, length 900mm
5. Sample dimensions: Graphite electrode Φ25×50mm
Graphite Carbon Detector
Model:
DSY-II
Specifications:
Specifications:
这里是占位文字
Gross weight (KG):
The graphite carbon detector uses imported data acquisition and control cards, and is computer-controlled to achieve fully automated testing, calculation, and reporting. A variety of instruments and equipment are available for graphite carbon detection to meet different needs.
Category:
You can send us an email:xtyqyb@163.com
InquireProduct Details
Graphite Carbon Detector Introduction:
| Name |
Model Number |
Technical Parameters and Standards |
| Carbon (Graphite) Permeability Tester |
DSY-II |
GB/T9973 Test Method for Permeability of Carbon Materials |
| Carbon (Graphite) Medium Temperature Thermal Conductivity Tester |
DR-SM |
GB/T8722 Test Method for Medium Temperature Thermal Conductivity of Graphite Materials 1. Room temperature - 1400℃ 2. Meets GD8722-2008 requirements 3. With atmosphere protection system 4. Computer automatic testing, controllable heating rate, fully automatic computer testing 5. Data printing output 4. Voltage measurement: Digital voltmeter, accuracy 0.01MV |
| Carbon (Graphite) Tensile Strength Tester |
SLW-I |
GB/T8721-2009 Test Method for Tensile Strength of Carbon Materials |
| Carbon (Graphite) Resistivity Tester |
WDT-II |
GB/T6717, GB/T 24525-2009, YS/T63.2 Test Method for Resistivity of Carbon Materials |
| Carbon (Graphite) Thermal Expansion Coefficient Tester |
Z RPY-14 00 |
GB/T3074.4 Test Method for Thermal Expansion Coefficient (CTE) of Graphite Electrodes 1. Maximum furnace temperature: Room temperature - 1400℃ 2. Heating rate: 0-20 degrees/min adjustable, computer program temperature control 5. Automatically records, stores, and prints data, prints temperature-expansion coefficient curve, temperature interval freely set, minimum interval 1℃ 8. Sample range: Ф6~10×50mm、10×10×50mm 9. Using imported linear bearing drive, realizing frictionless transmission of expansion value, transmission accuracy and repeatability 10. System measurement error: ±0.1-0.5% 12. The instrument is equipped with a standard computer interface, which can be connected to a general-purpose computer. All test operations are completed through the computer interface, which is easy to operate and learn, and provides a complete set of software (equipped with carbon industry detection software) |
| Carbon (Graphite) Apparent Porosity Tester |
DXR-II |
GB/T6156, GB/T24529 Test Method for Apparent Porosity of Carbon Materials |
| Carbon Material True Density Tester |
ZMY |
GB/T6155-2008 Test Method for True Density and True Porosity of Carbon Materials |
| Carbon (Graphite) Flexural Strength/Compressive Strength Tester |
SGW-II |
GB/T3074.1 Test Method for Flexural Strength of Graphite Electrodes GB/T1431 Test Method for Compressive Strength of Carbon Materials |
| High Temperature Compression and Bending Tester |
GKZ |
1. Test temperature 1350℃, 1600℃, computer program temperature control 2. Sample size range: 120/20/10 (length/width/height) ×4 (can be customized according to user requirements) 3. Maximum test pressure: 10000N 4. Hydraulic loading system, adjustable speed, pressure, automatic sample feeding 5. Computer data processing 6. Power supply: 380V, 12kw |
| Dynamic Elastic Modulus Tester (Carbon Materials) |
DTM-II |
Instrument reference standard: GB/T3074.2-2008 "Test Method for Elastic Modulus of Graphite Electrodes". This instrument uses imported data acquisition and control cards, and uses computer control to realize the automation of the entire testing, calculation, and reporting process. Main Technical Indicators 1. Frequency measurement range: 100Hz~50 kHz 2. Frequency resolution: 0.01Hz 3. Measurement error: <0.5% |
| Graphite Oxidizability Tester |
SG-YH
|
This equipment meets GB/T3074.3-2008 Test Method for Oxidizability of Graphite Electrodes and is used for the determination of the oxidizability of graphite electrodes. Main Technical Parameters: 1. Heating furnace operating temperature: Vertical, room temperature to 900℃ 2. Using microcomputer program temperature control, temperature control accuracy ±1℃, adjustable heating rate 3. Atmosphere can be introduced into the heating furnace chamber 4. Quartz tube: Outer diameter 64mm, inner diameter 56mm, length 900mm 5. Sample dimensions: Graphite electrode Φ25×50mm |
Relevant Specifications
Relevant Specifications
Recommend
Recommend
Inquire