Fully Automatic Thermal Conductivity Tester (Guarded Hot Plate Method)
零售价
¥ 55000
市场价
¥ 55000
库存
7
-
Specifications
-
DRPL-III-300 100℃ Flat plate heat flux meter method thermal conductivity meter
-
DRPL-III-300 300℃ Flat plate heat flux meter method thermal conductivity meter
-
You can send us an email:xtyqyb@163.com
Inquire库存剩余
7
隐藏域元素占位
- 产品描述
-
- Commodity name: Fully Automatic Thermal Conductivity Tester (Guarded Hot Plate Method)
- Model: Hunan Xiangke DRPL-III-300
Fully automatic thermal conductivity tester (guarded hot plate method) uses the popular heat flow meter method to detect thermal conductivity and thermal resistance, and is equipped with a computer to achieve fully automatic detection and generate experimental reports. It is suitable for testing the thermal conductivity of low thermal conductivity materials such as insulation materials and refractory materials. With an additional sample frame, it can also test powder materials. It is widely used in colleges and universities, research institutes, quality inspection departments, and factories.
Xiangke DRPL-III-300 Fully Automatic Thermal Conductivity Tester (Guarded Hot Plate Method)
I. Overview
Fully Automatic Thermal Conductivity Tester (Guarded Hot Plate Method) It adopts the popular hot plate method to detect thermal conductivity and thermal resistance. It is equipped with a computer to achieve fully automatic detection and generate experimental reports. It is suitable for testing the thermal conductivity of low-conductivity materials such as insulation materials and refractory materials. With the addition of sample frames, it can also test powder materials. It is widely used in colleges and universities, research institutes, quality inspection departments, and factories and mines.
This instrument refers to the following standards: JIS-1412-2 Determination of thermal resistance and thermal conductivity of thermal insulation materials, GB/T10295-2008, ISO 8301:1991 (Determination of steady-state thermal resistance and related properties of thermal insulation materials - Guarded hot plate method) and ASTM C518-04 Test method for determining steady-state heat flux and heat transfer properties using a heat flow meter.
II. System Composition:
1. Hot surface heater, high-precision programmable temperature control, hot surface temperature measurement resolution is 0.1℃,
2. The cold surface uses a constant temperature water bath for temperature control, with fluctuations less than 0.05 degrees, and a cold surface temperature measurement resolution of 0.01℃.
3. Equipped with a protective control device to effectively eliminate the influence of the environment on the test and ensure the accuracy and repeatability of the test.
4. Equipped with automatic pressurization and automatic thickness measurement functions, it can detect the thermal conductivity and thermal resistance under different pressures.
III. Main Parameters of Xiangke DRPL-III-300 Thermal Insulation Performance Tester (Guarded Hot Plate Method):
1. Thermal conductivity range and accuracy: 0.0010~3.0000W/mk, displaying four decimal places;
2. Measurement accuracy: 3%. Repeatability: ±1%.
3. Sample size: 300×300 (mm), thickness no more than 5-50mm. Special sizes can be customized.
4. Can test solid materials and powder materials.
5. Hot surface temperature and control: Room temperature ~100℃ (standard configuration), higher temperatures can be determined according to user requirements, such as room temperature to ~300℃. Flat heating plate, bidirectional thyristor control, temperature control accuracy 0.1℃.
6. Cold surface temperature and control: -5~99.9℃ (standard configuration), the cold surface uses water cooling to ensure the stability of the cold surface temperature (precision constant temperature water bath, adjustable temperature), temperature control accuracy 0.1℃.
7. The sample is clamped with computer-precise pressurization, pressure range 0-1000N, resolution 0.1N.
8. Automatic measurement of sample thickness, 0-50mm, resolution 0.01mm.
9. The test part uses a transparent organic glass windproof cover with a side door, allowing you to see the test situation inside the instrument.
10. Equipped with a protective control device to effectively eliminate the influence of the environment on the test and ensure the accuracy and repeatability of the test.
IV. Instrument Completeness
1. DRPL-III-300 thermal conductivity tester host 1 unit;
2. Test software (including communication interface) 1 set;
3. Constant temperature water bath and its controller 1 set;
4. Brand desktop computer 1 unit (can be provided by the purchaser).
Fully Automatic Thermal Conductivity Tester (Guarded Hot Plate Method)
Model:
Hunan Xiangke DRPL-III-300
Specifications:
Specifications:
这里是占位文字
Gross weight (KG):
Fully automatic thermal conductivity tester (guarded hot plate method) uses the popular heat flow meter method to detect thermal conductivity and thermal resistance, and is equipped with a computer to achieve fully automatic detection and generate experimental reports. It is suitable for testing the thermal conductivity of low thermal conductivity materials such as insulation materials and refractory materials. With an additional sample frame, it can also test powder materials. It is widely used in colleges and universities, research institutes, quality inspection departments, and factories.
Category:
You can send us an email:xtyqyb@163.com
InquireProduct Details
Xiangke DRPL-III-300 Fully Automatic Thermal Conductivity Tester (Guarded Hot Plate Method)
I. Overview
Fully Automatic Thermal Conductivity Tester (Guarded Hot Plate Method) It adopts the popular hot plate method to detect thermal conductivity and thermal resistance. It is equipped with a computer to achieve fully automatic detection and generate experimental reports. It is suitable for testing the thermal conductivity of low-conductivity materials such as insulation materials and refractory materials. With the addition of sample frames, it can also test powder materials. It is widely used in colleges and universities, research institutes, quality inspection departments, and factories and mines.
This instrument refers to the following standards: JIS-1412-2 Determination of thermal resistance and thermal conductivity of thermal insulation materials, GB/T10295-2008, ISO 8301:1991 (Determination of steady-state thermal resistance and related properties of thermal insulation materials - Guarded hot plate method) and ASTM C518-04 Test method for determining steady-state heat flux and heat transfer properties using a heat flow meter.
II. System Composition:
1. Hot surface heater, high-precision programmable temperature control, hot surface temperature measurement resolution is 0.1℃,
2. The cold surface uses a constant temperature water bath for temperature control, with fluctuations less than 0.05 degrees, and a cold surface temperature measurement resolution of 0.01℃.
3. Equipped with a protective control device to effectively eliminate the influence of the environment on the test and ensure the accuracy and repeatability of the test.
4. Equipped with automatic pressurization and automatic thickness measurement functions, it can detect the thermal conductivity and thermal resistance under different pressures.
III. Main Parameters of Xiangke DRPL-III-300 Thermal Insulation Performance Tester (Guarded Hot Plate Method):
1. Thermal conductivity range and accuracy: 0.0010~3.0000W/mk, displaying four decimal places;
2. Measurement accuracy: 3%. Repeatability: ±1%.
3. Sample size: 300×300 (mm), thickness no more than 5-50mm. Special sizes can be customized.
4. Can test solid materials and powder materials.
5. Hot surface temperature and control: Room temperature ~100℃ (standard configuration), higher temperatures can be determined according to user requirements, such as room temperature to ~300℃. Flat heating plate, bidirectional thyristor control, temperature control accuracy 0.1℃.
6. Cold surface temperature and control: -5~99.9℃ (standard configuration), the cold surface uses water cooling to ensure the stability of the cold surface temperature (precision constant temperature water bath, adjustable temperature), temperature control accuracy 0.1℃.
7. The sample is clamped with computer-precise pressurization, pressure range 0-1000N, resolution 0.1N.
8. Automatic measurement of sample thickness, 0-50mm, resolution 0.01mm.
9. The test part uses a transparent organic glass windproof cover with a side door, allowing you to see the test situation inside the instrument.
10. Equipped with a protective control device to effectively eliminate the influence of the environment on the test and ensure the accuracy and repeatability of the test.
IV. Instrument Completeness
1. DRPL-III-300 thermal conductivity tester host 1 unit;
2. Test software (including communication interface) 1 set;
3. Constant temperature water bath and its controller 1 set;
4. Brand desktop computer 1 unit (can be provided by the purchaser).
Relevant Specifications
Relevant Specifications
Recommend
Recommend
Inquire
If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!