Product

High-Temperature Flat Plate Thermal Conductivity Meter


A guarded hot plate method is used in the high-temperature flat plate thermal conductivity meter to detect the thermal conductivity of insulation materials at high temperatures. The flat plate thermal conductivity meter is suitable for testing the thermal conductivity of refractory insulation, ceramic fiber, felt, textiles, plates, and bricks at different temperatures.

零售价

¥ 55000

市场价

¥ 55000

库存

30

  • Specifications
    • DRS-3A-1200 DRS-3A-1200 High temperature flat plate thermal conductivity meter
    • DRS-3A-1500 DRS-3A-1500 High temperature flat plate thermal conductivity meter
    • DRS-3B-1200(vacuum type) DRS-3B-1200(vacuum type) High temperature flat plate thermal conductivity meter
    • DRS-3B-1500(vacuum type) DRS-3B-1500(vacuum type)High temperature flat plate thermal conductivity meter
    • DRS-4A-800 DRS-4A-800 High temperature flat plate thermal conductivity meter
    • DRS-4A-1200 DRS-4A-1200 High temperature flat plate thermal conductivity meter
    • 10L low-temperature constant temperature bath 10L low-temperature constant temperature bath equipped with DRS-3A
    • 50L low-temperature constant temperature bath 50L low-temperature constant temperature bath equipped with DRS-3B

You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
Quantity
-
+

库存剩余

30

隐藏域元素占位

  • 产品描述
    • Commodity name: High-Temperature Flat Plate Thermal Conductivity Meter
    • Model: Hunan Xiangke DRS

    A guarded hot plate method is used in the high-temperature flat plate thermal conductivity meter to detect the thermal conductivity of insulation materials at high temperatures. The flat plate thermal conductivity meter is suitable for testing the thermal conductivity of refractory insulation, ceramic fiber, felt, textiles, plates, and bricks at different temperatures.

    I. High Temperature Flat Plate Thermal Conductivity Meter Overview

    The flat plate thermal conductivity meter is a high-temperature thermal conductivity testing instrument for insulation materials, developed based on our factory's DRS-2 water flow flat plate thermal conductivity testing instrument. Compared with DRS-2, it improves resolution and automation, shortens testing time, is easier to maintain, and has more reliable instrument performance. This instrument is suitable for testing the thermal conductivity of refractory insulation, ceramic fiber, felt, textiles, plates, and bricks at different temperatures. The flat plate thermal conductivity meter is widely used in colleges and universities, research institutions, quality inspection departments, and material analysis and testing in manufacturing plants.

    Reference Standards for Flat Plate Thermal Conductivity Meter: ASTM C518-04 Test Method for Determining Steady-State Heat Flux and Thermal Transmission Properties Using a Heat Flow Meter; GB10295-2008 Determination of Steady-State Thermal Resistance and Related Properties of Thermal Insulation Materials (Heat Flow Meter Method); YB/T 4130-2005 Refractory Materials Thermal Conductivity Test Method (Water Flow Flat Plate Method); GB/T 17911-2018 Refractory Ceramic Fiber Products Thermal Conductivity Test Method, etc.

    II. Xiangke DRS High Temperature Flat Plate Thermal Conductivity Meter Main Technical Parameters

    The DRS series flat plate thermal conductivity meter is mainly used for the thermal conductivity detection of thermal insulation materials at high temperatures. DRS-3B has a vacuum atmosphere protection function to prevent sample oxidation.

    Instrument Model Specifications

    DRS-3

    DRS-3A

    DRS-3B

    1. Thermal Conductivity Range

    0.0010-3W/mk

    0.0010-3W/mk

    0.0010-3W/mk

    2. Testing Accuracy

    ±5%

    ±5%

    ±5%

    3. Hot Surface Temperature Range

    100-1200℃

    100-1200℃

    100-1200℃

    4. Calorimetric Temperature Control Method

    Constant Temperature Water Bath

    Semiconductor Refrigeration

    Semiconductor Refrigeration

    5. Heat Protection Temperature Control Method

    Semiconductor Refrigeration

    Semiconductor Refrigeration

    Semiconductor Refrigeration

    6. Calorimetric Plate Size

    75×75 (mm)

    75×75 (mm)

    75×75 (mm)

    7. Heat Flow Meter Size

    75×75 (mm)

    75×75 (mm)

    75×75 (mm)

    8. Number of Sample Temperature Measurement Points

    4

    4

    4

    9. Sample Atmosphere Environment

    Air

    Air

    -0.095MPa; Atmosphere Protection

    10. Sample Size

    200×200~250×250 (mm); Thickness 10~100 (mm)

    11. Measurement and Control Method

    Fully automatic computer testing and data processing, and can generate test reports and print output.

    12. Main Unit Power Supply

    Voltage 220V; Frequency 50Hz; Total Power ≤5KW

    13. Instrument Configuration

    Includes one DRS-3 testing host, one software set, one set of testing thermocouples, one high-precision constant temperature water bath, and one desktop computer (can be provided by the purchaser).

    Includes one DRS-3A testing host, one software set, one set of testing thermocouples, one roll of rubber tubing (instrument needs to be connected to tap water), and one desktop computer (can be provided by the purchaser).

    Includes one DRS-3B testing host, one software set, one set of testing thermocouples, one roll of rubber tubing (instrument needs to be connected to tap water), one vacuum sealing device, one vacuum pump, and one desktop computer (can be provided by the purchaser).

    14. Optional

    Multi-layer testing can be optionally configured according to customer requirements. Each additional layer requires an additional testing thermocouple, and the cost will be calculated separately.

    Both DRS-4 and DRS-4A are electrically pressurized and automatically measure thickness. The difference is that the DRS-4 hot plate uses heat-resistant stainless steel, with a slightly lower operating temperature, while the DRS-4A hot plate uses silicon carbide, with slightly lower pressure resistance, and the thickness measurement requires an additional thickness correction system, but the hot surface operating temperature is higher.

    Instrument Model Specifications

    DRS-4

    DRS-4A

    1. Thermal Conductivity Range

    0.001-3W/mk

    0.001-3W/mk

    2. Testing Accuracy

    Better than 5%

    Better than 5%

    3. Hot Surface Temperature Range

    200-800℃

    200-1200℃

    4. Calorimetric Temperature Control Method

    Semiconductor Refrigeration

    Semiconductor Refrigeration

    5. Heat Protection Temperature Control Method

    Semiconductor Refrigeration

    Semiconductor Refrigeration

    6. Calorimetric Plate Size

    75×75 (mm)

    75×75 (mm)

    7. Heat Flow Meter Size

    75×75 (mm)

    75×75 (mm)

    8. Number of Sample Temperature Measurement Points

    4

    4

    9. Loading and Unloading Method

    Electric

    Electric

    10. Pressure Range

    0-1000 (N)

    0-500 (N)

    11. Thickness Measurement Range

    0-120 (mm)

    0-120 (mm)

    12. Thickness Correction

    Experimental Correction

    Displacement Meter Instantaneous Correction

    13. Sample Atmosphere Environment

    Air

    Air

    14. Sample Size

    200×200~250×250 (mm); Thickness 10~100 (mm)

    15. Measurement and Control Method

    Fully automatic computer testing and data processing, and can generate test reports and print output.

    16. Main Unit Power Supply

    Voltage 220V; Frequency 50Hz; Total Power ≤5KW

    17. Instrument Configuration

    Includes one DRS-4 testing host, one software set, one set of testing thermocouples, one roll of rubber tubing (instrument needs to be connected to tap water), and one desktop computer (can be provided by the purchaser).

    Includes one DRS-4A test host, one software suite, one set of test thermocouples, one roll of rubber tubing (instrument requires connection to tap water), and one desktop computer (can be provided by the purchaser).

    18. Optional Item 1

    A constant temperature water bath can be optionally selected according to customer requirements, with the circulating water replacing tap water.

    19. Optional Item 2

    Multi-layer testing can be optionally configured according to customer requirements. Each additional layer requires an additional testing thermocouple, and the cost will be calculated separately.

    Note: Hot surface temperature specifications of 1500℃ can also be customized according to user requirements.

     

     

     

High-Temperature Flat Plate Thermal Conductivity Meter


Model:

Hunan Xiangke DRS

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


A guarded hot plate method is used in the high-temperature flat plate thermal conductivity meter to detect the thermal conductivity of insulation materials at high temperatures. The flat plate thermal conductivity meter is suitable for testing the thermal conductivity of refractory insulation, ceramic fiber, felt, textiles, plates, and bricks at different temperatures.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

I. High Temperature Flat Plate Thermal Conductivity Meter Overview

The flat plate thermal conductivity meter is a high-temperature thermal conductivity testing instrument for insulation materials, developed based on our factory's DRS-2 water flow flat plate thermal conductivity testing instrument. Compared with DRS-2, it improves resolution and automation, shortens testing time, is easier to maintain, and has more reliable instrument performance. This instrument is suitable for testing the thermal conductivity of refractory insulation, ceramic fiber, felt, textiles, plates, and bricks at different temperatures. The flat plate thermal conductivity meter is widely used in colleges and universities, research institutions, quality inspection departments, and material analysis and testing in manufacturing plants.

Reference Standards for Flat Plate Thermal Conductivity Meter: ASTM C518-04 Test Method for Determining Steady-State Heat Flux and Thermal Transmission Properties Using a Heat Flow Meter; GB10295-2008 Determination of Steady-State Thermal Resistance and Related Properties of Thermal Insulation Materials (Heat Flow Meter Method); YB/T 4130-2005 Refractory Materials Thermal Conductivity Test Method (Water Flow Flat Plate Method); GB/T 17911-2018 Refractory Ceramic Fiber Products Thermal Conductivity Test Method, etc.

II. Xiangke DRS High Temperature Flat Plate Thermal Conductivity Meter Main Technical Parameters

The DRS series flat plate thermal conductivity meter is mainly used for the thermal conductivity detection of thermal insulation materials at high temperatures. DRS-3B has a vacuum atmosphere protection function to prevent sample oxidation.

Instrument Model Specifications

DRS-3

DRS-3A

DRS-3B

1. Thermal Conductivity Range

0.0010-3W/mk

0.0010-3W/mk

0.0010-3W/mk

2. Testing Accuracy

±5%

±5%

±5%

3. Hot Surface Temperature Range

100-1200℃

100-1200℃

100-1200℃

4. Calorimetric Temperature Control Method

Constant Temperature Water Bath

Semiconductor Refrigeration

Semiconductor Refrigeration

5. Heat Protection Temperature Control Method

Semiconductor Refrigeration

Semiconductor Refrigeration

Semiconductor Refrigeration

6. Calorimetric Plate Size

75×75 (mm)

75×75 (mm)

75×75 (mm)

7. Heat Flow Meter Size

75×75 (mm)

75×75 (mm)

75×75 (mm)

8. Number of Sample Temperature Measurement Points

4

4

4

9. Sample Atmosphere Environment

Air

Air

-0.095MPa; Atmosphere Protection

10. Sample Size

200×200~250×250 (mm); Thickness 10~100 (mm)

11. Measurement and Control Method

Fully automatic computer testing and data processing, and can generate test reports and print output.

12. Main Unit Power Supply

Voltage 220V; Frequency 50Hz; Total Power ≤5KW

13. Instrument Configuration

Includes one DRS-3 testing host, one software set, one set of testing thermocouples, one high-precision constant temperature water bath, and one desktop computer (can be provided by the purchaser).

Includes one DRS-3A testing host, one software set, one set of testing thermocouples, one roll of rubber tubing (instrument needs to be connected to tap water), and one desktop computer (can be provided by the purchaser).

Includes one DRS-3B testing host, one software set, one set of testing thermocouples, one roll of rubber tubing (instrument needs to be connected to tap water), one vacuum sealing device, one vacuum pump, and one desktop computer (can be provided by the purchaser).

14. Optional

Multi-layer testing can be optionally configured according to customer requirements. Each additional layer requires an additional testing thermocouple, and the cost will be calculated separately.

Both DRS-4 and DRS-4A are electrically pressurized and automatically measure thickness. The difference is that the DRS-4 hot plate uses heat-resistant stainless steel, with a slightly lower operating temperature, while the DRS-4A hot plate uses silicon carbide, with slightly lower pressure resistance, and the thickness measurement requires an additional thickness correction system, but the hot surface operating temperature is higher.

Instrument Model Specifications

DRS-4

DRS-4A

1. Thermal Conductivity Range

0.001-3W/mk

0.001-3W/mk

2. Testing Accuracy

Better than 5%

Better than 5%

3. Hot Surface Temperature Range

200-800℃

200-1200℃

4. Calorimetric Temperature Control Method

Semiconductor Refrigeration

Semiconductor Refrigeration

5. Heat Protection Temperature Control Method

Semiconductor Refrigeration

Semiconductor Refrigeration

6. Calorimetric Plate Size

75×75 (mm)

75×75 (mm)

7. Heat Flow Meter Size

75×75 (mm)

75×75 (mm)

8. Number of Sample Temperature Measurement Points

4

4

9. Loading and Unloading Method

Electric

Electric

10. Pressure Range

0-1000 (N)

0-500 (N)

11. Thickness Measurement Range

0-120 (mm)

0-120 (mm)

12. Thickness Correction

Experimental Correction

Displacement Meter Instantaneous Correction

13. Sample Atmosphere Environment

Air

Air

14. Sample Size

200×200~250×250 (mm); Thickness 10~100 (mm)

15. Measurement and Control Method

Fully automatic computer testing and data processing, and can generate test reports and print output.

16. Main Unit Power Supply

Voltage 220V; Frequency 50Hz; Total Power ≤5KW

17. Instrument Configuration

Includes one DRS-4 testing host, one software set, one set of testing thermocouples, one roll of rubber tubing (instrument needs to be connected to tap water), and one desktop computer (can be provided by the purchaser).

Includes one DRS-4A test host, one software suite, one set of test thermocouples, one roll of rubber tubing (instrument requires connection to tap water), and one desktop computer (can be provided by the purchaser).

18. Optional Item 1

A constant temperature water bath can be optionally selected according to customer requirements, with the circulating water replacing tap water.

19. Optional Item 2

Multi-layer testing can be optionally configured according to customer requirements. Each additional layer requires an additional testing thermocouple, and the cost will be calculated separately.

Note: Hot surface temperature specifications of 1500℃ can also be customized according to user requirements.

 

 

 

Relevant Specifications

Relevant Specifications

Inquire

If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!

Submit