Guard Plate Heat Flow Meter Thermal Conductivity Tester
零售价
¥ 40000
市场价
¥ 40000
库存
14
-
Specifications
-
DRPL-III-300 100℃ Thermal conductivity meter for insulation materials
-
DRPL-III-300 300℃ Thermal conductivity meter for insulation materials
-
DRPL-300 100℃ Thermal conductivity meter for insulation materials
-
DRPL-300 300℃ Thermal conductivity meter for insulation materials
-
You can send us an email:xtyqyb@163.com
Inquire库存剩余
14
隐藏域元素占位
- 产品描述
-
- Commodity name: Guard Plate Heat Flow Meter Thermal Conductivity Tester
- Model: DRPL-300
The Xiangtan Xiangke DRPL-300 Protective Flat Plate Heat Flow Meter Thermal Conductivity Tester primarily tests the thermal conductivity of homogeneous plate-like materials such as plastics, rubber, glass, fiberboard, polystyrene board, extruded board, foamed concrete, hollow glass, wood, and various insulation materials. It can also measure the thermal conductivity of various substances such as granular materials, loose materials, and soft materials. With the addition of a protective control device, environmental influences on the test can be effectively eliminated, ensuring testing accuracy and repeatability.
Xiangtan Xiangke DRPL-300 Guarded Hot Plate Thermal Conductivity Tester
I. Scope of Application:
1. The thermal conductivity meter is mainly used to test the thermal conductivity of homogeneous plate-like materials such as plastics, rubber, glass, fiberboard, polystyrene board, extruded board, foamed concrete, hollow glass, wood, and various insulation materials. It can also measure the thermal conductivity of various substances such as granular materials, loose materials, and soft materials. With the addition of a protective control device, it can effectively eliminate the influence of the environment on the test, ensuring testing accuracy and repeatability.
II. Standards Compliance:
Complies with GB/T10295-2008 "Determination of steady-state thermal resistance and related properties of thermal insulation materials - Guarded hot plate method" and ISO/DIS8301 "Thermal insulation - Determination of steady-state thermal resistance and related properties - Guarded hot plate apparatus".
III. Xiangtan Xiangke DRPL-300 Guarded Hot Plate Thermal Conductivity Tester Main Technical Parameters
1. Thermal conductivity measurement and display range: 0.001-3.000 W/(m·k);
2. Measurement accuracy: ±3%.
3. Testable sample size: 300 × 300 × (10-50) (mm).
4. Testable solid and powder materials.
5. Measurement time: Approximately 2 hours.
6. Hot surface temperature and control: Required from room temperature to -100℃. Plate heater, temperature control accuracy must reach ±0.1℃.Note: Hot surface temperature can be customized according to customer requirements, with specifications ranging from room temperature to 200 ℃ and room temperature to 300 ℃.
7. Cold surface temperature and control: 5-99.9℃ (standard configuration, with one 0-99.99℃ constant temperature water bath), water-cooled cold surface to ensure stable cold surface temperature (precision constant temperature water bath, adjustable temperature), temperature control accuracy 0.1℃.
8. Uses a heat flow meter, stable and reliable performance.
9. The entire process uses computer automatic testing and stores and prints experimental data.
IV. Instrument Completeness1. DRPL-300 thermal conductivity tester main unit 1 set;
2. Testing software (including communication interface) 1 set;
3. Constant temperature water bath and its controller 1 set;
4. Lenovo desktop computer 1 set (configured according to the contract, can be provided by the purchaser).

Note: Automatic pressurization and automatic thickness measurement functions can be optionally configured according to customer requirements to perform tests under different pressure conditions (i.e., DRPL-III-300):
a. Uses a high-precision displacement sensor and connects to a computer for automatic thickness measurement, measurement range 0-50mm, resolution 0.01mm;
b. Automatic pressurization, detection of thermal conductivity under different pressure conditions, adjustable pressurization range 0-1000N, resolution 0.1N.

Guard Plate Heat Flow Meter Thermal Conductivity Tester
Model:
DRPL-300
Specifications:
Specifications:
这里是占位文字
Gross weight (KG):
The Xiangtan Xiangke DRPL-300 Protective Flat Plate Heat Flow Meter Thermal Conductivity Tester primarily tests the thermal conductivity of homogeneous plate-like materials such as plastics, rubber, glass, fiberboard, polystyrene board, extruded board, foamed concrete, hollow glass, wood, and various insulation materials. It can also measure the thermal conductivity of various substances such as granular materials, loose materials, and soft materials. With the addition of a protective control device, environmental influences on the test can be effectively eliminated, ensuring testing accuracy and repeatability.
Category:
You can send us an email:xtyqyb@163.com
InquireProduct Details
Xiangtan Xiangke DRPL-300 Guarded Hot Plate Thermal Conductivity Tester
I. Scope of Application:
1. The thermal conductivity meter is mainly used to test the thermal conductivity of homogeneous plate-like materials such as plastics, rubber, glass, fiberboard, polystyrene board, extruded board, foamed concrete, hollow glass, wood, and various insulation materials. It can also measure the thermal conductivity of various substances such as granular materials, loose materials, and soft materials. With the addition of a protective control device, it can effectively eliminate the influence of the environment on the test, ensuring testing accuracy and repeatability.
II. Standards Compliance:
Complies with GB/T10295-2008 "Determination of steady-state thermal resistance and related properties of thermal insulation materials - Guarded hot plate method" and ISO/DIS8301 "Thermal insulation - Determination of steady-state thermal resistance and related properties - Guarded hot plate apparatus".
III. Xiangtan Xiangke DRPL-300 Guarded Hot Plate Thermal Conductivity Tester Main Technical Parameters
1. Thermal conductivity measurement and display range: 0.001-3.000 W/(m·k);
2. Measurement accuracy: ±3%.
3. Testable sample size: 300 × 300 × (10-50) (mm).
4. Testable solid and powder materials.
5. Measurement time: Approximately 2 hours.
6. Hot surface temperature and control: Required from room temperature to -100℃. Plate heater, temperature control accuracy must reach ±0.1℃.
Note: Hot surface temperature can be customized according to customer requirements, with specifications ranging from room temperature to 200 ℃ and room temperature to 300 ℃.
7. Cold surface temperature and control: 5-99.9℃ (standard configuration, with one 0-99.99℃ constant temperature water bath), water-cooled cold surface to ensure stable cold surface temperature (precision constant temperature water bath, adjustable temperature), temperature control accuracy 0.1℃.
8. Uses a heat flow meter, stable and reliable performance.
9. The entire process uses computer automatic testing and stores and prints experimental data.
IV. Instrument Completeness
1. DRPL-300 thermal conductivity tester main unit 1 set;
2. Testing software (including communication interface) 1 set;
3. Constant temperature water bath and its controller 1 set;
4. Lenovo desktop computer 1 set (configured according to the contract, can be provided by the purchaser).

Note: Automatic pressurization and automatic thickness measurement functions can be optionally configured according to customer requirements to perform tests under different pressure conditions (i.e., DRPL-III-300):
a. Uses a high-precision displacement sensor and connects to a computer for automatic thickness measurement, measurement range 0-50mm, resolution 0.01mm;
b. Automatic pressurization, detection of thermal conductivity under different pressure conditions, adjustable pressurization range 0-1000N, resolution 0.1N.

Relevant Specifications
Relevant Specifications
Recommend
Recommend
Inquire
If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!