Fully Automatic Dual-Plate Thermal Conductivity Tester
零售价
¥ 68000
市场价
¥ 68000
库存
5
-
Specifications
-
DRH-II-300 Fully automatic dual plate thermal conductivity meter
-
You can send us an email:xtyqyb@163.com
Inquire库存剩余
5
隐藏域元素占位
- 产品描述
-
- Commodity name: Fully Automatic Dual-Plate Thermal Conductivity Tester
- Model: Xiangke DRH-II-300
The Xiangke DRH-II-300 fully automatic dual-plate thermal conductivity tester is based on the principle of unidirectional steady-state heat conduction. When the upper and lower surfaces of the sample are at different stable temperatures, the heat flow through the effective heat transfer area of the sample, the temperature difference between the two surfaces of the sample, and the thickness are measured to calculate the thermal conductivity. It meets the high-precision testing requirements of material thermal conductivity for material testing and research departments. It mainly tests plastics, glass, fibers, foams, insulation materials, etc. It is widely used in colleges and universities, scientific research units, quality inspection departments, and material analysis and testing in production plants.
Xiangke DRH-II-300 Fully Automatic Thermal Conductivity Tester (Guarded Hot Plate Method, Double Plate)
This instrument is based on the principle of unidirectional steady-state heat conduction. When the upper and lower surfaces of the sample are at different stable temperatures, the heat flow through the effective heat transfer area of the sample, the temperature difference between the two surfaces of the sample, and the thickness are measured to calculate the thermal conductivity. It meets the high-precision testing requirements of material thermal conductivity for material testing and research departments. It mainly tests plastics, glass, fibers, foams, insulation materials, etc. It is widely used in colleges and universities, scientific research units, quality inspection departments, and material analysis and testing in manufacturing plants.
Instrument Reference Standards:
GB/10294-2008 (Determination of steady-state thermal resistance and related properties of thermal insulation materials Guarded hot plate method);
GB/T3399-1982 (Test method for thermal conductivity of plastics, guarded hot plate method);
GB/T3139-2005 (Test method for thermal conductivity of fiber reinforced plastics) (Test method for thermal conductivity of fiberglass).
GB/T10801.1-2002 (Extruded Polystyrene Foam Plastics for Thermal Insulation) requirements for the measurement of the thermal conductivity of rigid polyurethane foam materials;
GB/T10801.2-2002 (Extruded Polystyrene Foam Plastics (XPS) for Thermal Insulation) requirements for the measurement of the thermal conductivity of extruded polystyrene foam plastics;
GB/T3139-2005 (Test method for thermal conductivity of fiber reinforced plastics);
GB/T 17794-2008 (Flexible foam rubber and plastic thermal insulation products) requirements for the measurement of thermal conductivity.
Xiangke DRH-II-300 Fully Automatic Double-Plate Thermal Conductivity Tester Performance Characteristics:
1. Automatic thickness measurement: Using a high-precision displacement sensor for measurement and connecting to a computer for automatic thickness measurement, reducing human error.
2. Automatic pressurization system: Computer automatic pressurization, can test the thermal conductivity under different pressures, more scientific than manual pressurization, more data-based, and better repeatability.
3. Using double-plate detection for higher accuracy.
Main Technical Indicators:
1. Thermal conductivity range: 0.0010~2.000W/mk;
2. Test accuracy: ±3%;
3. Sample size: Double specimen 300×300×(10-50)mm; Planarity: < 0.05 mm.
4. Hot surface temperature range: Room temperature~100℃, temperature resolution 0.01℃, measurement accuracy: 0.05℃;
5. Cold surface temperature range: 0~60℃, temperature resolution 0.01℃;
6. Computer-controlled fully automatic testing, data processing, and generation of test reports, which can be printed;
7. A high-precision displacement sensor is used and connected to a computer for automatic thickness measurement, with a measurement range of 0---50mm and a resolution of 0.01mm;
8. Automatic pressurization is available to detect the thermal conductivity under different pressure conditions, with an adjustable pressurization range of 0---1000N and a resolution of 0.1N.
9. Cold and hot plate temperature difference: The default value is 20℃, and the user can also set it themselves.
Common standard temperature difference: 20℃ Common temperature difference range 15-25℃
Configuration: Including Xiangke DRH-II-300 Fully Automatic Double-Plate Thermal Conductivity Tester One testing host, one software, one high-precision constant temperature water bath, one desktop computer (as configured in the contract).
Fully Automatic Dual-Plate Thermal Conductivity Tester
Model:
Xiangke DRH-II-300
Specifications:
Specifications:
这里是占位文字
Gross weight (KG):
The Xiangke DRH-II-300 fully automatic dual-plate thermal conductivity tester is based on the principle of unidirectional steady-state heat conduction. When the upper and lower surfaces of the sample are at different stable temperatures, the heat flow through the effective heat transfer area of the sample, the temperature difference between the two surfaces of the sample, and the thickness are measured to calculate the thermal conductivity. It meets the high-precision testing requirements of material thermal conductivity for material testing and research departments. It mainly tests plastics, glass, fibers, foams, insulation materials, etc. It is widely used in colleges and universities, scientific research units, quality inspection departments, and material analysis and testing in production plants.
Category:
You can send us an email:xtyqyb@163.com
InquireProduct Details
Xiangke DRH-II-300 Fully Automatic Thermal Conductivity Tester (Guarded Hot Plate Method, Double Plate)
This instrument is based on the principle of unidirectional steady-state heat conduction. When the upper and lower surfaces of the sample are at different stable temperatures, the heat flow through the effective heat transfer area of the sample, the temperature difference between the two surfaces of the sample, and the thickness are measured to calculate the thermal conductivity. It meets the high-precision testing requirements of material thermal conductivity for material testing and research departments. It mainly tests plastics, glass, fibers, foams, insulation materials, etc. It is widely used in colleges and universities, scientific research units, quality inspection departments, and material analysis and testing in manufacturing plants.
Instrument Reference Standards:
GB/10294-2008 (Determination of steady-state thermal resistance and related properties of thermal insulation materials Guarded hot plate method);
GB/T3399-1982 (Test method for thermal conductivity of plastics, guarded hot plate method);
GB/T3139-2005 (Test method for thermal conductivity of fiber reinforced plastics) (Test method for thermal conductivity of fiberglass).
GB/T10801.1-2002 (Extruded Polystyrene Foam Plastics for Thermal Insulation) requirements for the measurement of the thermal conductivity of rigid polyurethane foam materials;
GB/T10801.2-2002 (Extruded Polystyrene Foam Plastics (XPS) for Thermal Insulation) requirements for the measurement of the thermal conductivity of extruded polystyrene foam plastics;
GB/T3139-2005 (Test method for thermal conductivity of fiber reinforced plastics);
GB/T 17794-2008 (Flexible foam rubber and plastic thermal insulation products) requirements for the measurement of thermal conductivity.
Xiangke DRH-II-300 Fully Automatic Double-Plate Thermal Conductivity Tester Performance Characteristics:
1. Automatic thickness measurement: Using a high-precision displacement sensor for measurement and connecting to a computer for automatic thickness measurement, reducing human error.
2. Automatic pressurization system: Computer automatic pressurization, can test the thermal conductivity under different pressures, more scientific than manual pressurization, more data-based, and better repeatability.
3. Using double-plate detection for higher accuracy.
Main Technical Indicators:
1. Thermal conductivity range: 0.0010~2.000W/mk;
2. Test accuracy: ±3%;
3. Sample size: Double specimen 300×300×(10-50)mm; Planarity: < 0.05 mm.
4. Hot surface temperature range: Room temperature~100℃, temperature resolution 0.01℃, measurement accuracy: 0.05℃;
5. Cold surface temperature range: 0~60℃, temperature resolution 0.01℃;
6. Computer-controlled fully automatic testing, data processing, and generation of test reports, which can be printed;
7. A high-precision displacement sensor is used and connected to a computer for automatic thickness measurement, with a measurement range of 0---50mm and a resolution of 0.01mm;
8. Automatic pressurization is available to detect the thermal conductivity under different pressure conditions, with an adjustable pressurization range of 0---1000N and a resolution of 0.1N.
9. Cold and hot plate temperature difference: The default value is 20℃, and the user can also set it themselves.
Common standard temperature difference: 20℃ Common temperature difference range 15-25℃
Configuration: Including Xiangke DRH-II-300 Fully Automatic Double-Plate Thermal Conductivity Tester One testing host, one software, one high-precision constant temperature water bath, one desktop computer (as configured in the contract).
Relevant Specifications
Relevant Specifications
Recommend
Recommend
Inquire
If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!