Specifications
-
DRL-3 (Standard Type) Thermal conductivity meter (heat flow method)
-
DRL-3 (Enhanced Type) Thermal conductivity meter (heat flow method)
-
DRL-3P (Vacuum Type) Thermal conductivity meter (heat flow method)
-
You can send us an email:xtyqyb@163.com
Inquire库存剩余
14
隐藏域元素占位
- 产品描述
-
- Commodity name: Thermal Conductivity Tester, Heat Flow Method
- Model: Hunan Xiangke DRL-III
The Xiangke DRL-III thermal conductivity tester, a heat flow thermal conductivity instrument, is mainly used to test the thermal conductivity and thermal resistance of thin thermal conductors, solid electrical insulating materials, thermally conductive silicone, rubber, thermally conductive resin, beryllium oxide ceramics, and aluminum oxide ceramics. The instrument has added a pressurizing device and a thickness measuring device, which can detect the thermal conductivity and thermal resistance of materials under different pressure conditions.
Xiangke DRL-III Thermal Conductivity Tester, Heat Flow Method Thermal Conductivity Meter, Thermal Analysis Instrument, Thermal Resistance Tester
I. Overview
This instrument is mainly used to test the thermal resistance of thin thermal conductors, solid electrical insulating materials, thermally conductive resins, silicone rubber and grease, rubber, plastics, beryllium oxide ceramics, alumina ceramics and other small materials, as well as the contact thermal resistance at the solid interface and the thermal conductivity of the materials. The test material is in the form of solid flakes. With a frame, it can also test powder and paste materials.
Instrument reference standards: MIL-I-49456A (insulating sheets, thermally conductive resins, thermally conductive fiberglass reinforced); GB 5598-85 (determination method of thermal conductivity of beryllium oxide ceramics); ASTM-D5470-12 (test standard for heat transfer performance of thin thermally conductive solid electrical insulating materials), etc.
Instrument features: automatic pressurization, automatic thickness measurement, fully automatic experimental control. 6-point temperature gradient detection to improve testing accuracy. It can detect the thermal resistance curve under different pressures, uses an optimized mathematical model to measure the thermal conductivity and thermal resistance of materials, and the contact thermal resistance at the interface.
Widely used in colleges and universities, scientific research units, quality inspection departments and manufacturing plants for material analysis and testing.
II. Xiangke DRL-III Thermal Conductivity Tester, Heat Flow Method Main Parameters
Main Parameters
DRL-3 (Standard Type)
DRL-3 (Enhanced Type)
DRL-3P (Vacuum Type)
1. Sample Size
≤Φ30mm
≤Φ30mm
≤Φ30mm
2. Sample Thickness
0.02-20mm
0.02-20mm
0.02-20mm
3. Hot-end Temperature
Room temperature - 99.99℃
Room temperature - 200℃
Room temperature - 100℃
4. Cold-end Temperature
0-99.0℃
0-99.0℃
0-99.0℃
5. Thermal Conductivity
0.1~45 W/m*k
0.05~45 W/m*k
0.05~45 W/m*k
6. Thermal Resistance (m2*K/W)
0.000005~0.05
0.000005~0.05
0.000005~0.05
7. Testing Accuracy
≤3%
≤3%
≤3%
7. Pressure Measurement
0~1000N
0~1000N
0~1000N
8. Displacement Measurement
0~40mm
0~40mm
0~40mm
9. Pressure Control
Electric
Electric
Electric
10. Testing Environment
Air
Air
Vacuum
10. Experimental Methods
a. Thermal resistance test of samples under different pressures.
b. Thermal conductivity test of materials.
c. Contact thermal resistance test.
d. Thermal resistance test of aluminum substrates (composite materials).
e. Aging reliability test.
11. Power Supply
Voltage: 220V, Power less than 1KW.
Instrument Selection: The DRL-3 (Enhanced Type) is based on the DRL-3 (Standard Type) with improved hot-end temperature, mainly used for testing materials with slightly higher temperature requirements and slightly lower thermal conductivity; DRL-3P is mainly used for testing materials that are easily oxidized and require a vacuum testing environment.
下一页
Thermal Conductivity Tester, Heat Flow Method
Model:
Hunan Xiangke DRL-III
Specifications:
Specifications:
这里是占位文字
Gross weight (KG):
The Xiangke DRL-III thermal conductivity tester, a heat flow thermal conductivity instrument, is mainly used to test the thermal conductivity and thermal resistance of thin thermal conductors, solid electrical insulating materials, thermally conductive silicone, rubber, thermally conductive resin, beryllium oxide ceramics, and aluminum oxide ceramics. The instrument has added a pressurizing device and a thickness measuring device, which can detect the thermal conductivity and thermal resistance of materials under different pressure conditions.
Category:
You can send us an email:xtyqyb@163.com
InquireProduct Details
Xiangke DRL-III Thermal Conductivity Tester, Heat Flow Method Thermal Conductivity Meter, Thermal Analysis Instrument, Thermal Resistance Tester
I. Overview
This instrument is mainly used to test the thermal resistance of thin thermal conductors, solid electrical insulating materials, thermally conductive resins, silicone rubber and grease, rubber, plastics, beryllium oxide ceramics, alumina ceramics and other small materials, as well as the contact thermal resistance at the solid interface and the thermal conductivity of the materials. The test material is in the form of solid flakes. With a frame, it can also test powder and paste materials.
Instrument reference standards: MIL-I-49456A (insulating sheets, thermally conductive resins, thermally conductive fiberglass reinforced); GB 5598-85 (determination method of thermal conductivity of beryllium oxide ceramics); ASTM-D5470-12 (test standard for heat transfer performance of thin thermally conductive solid electrical insulating materials), etc.
Instrument features: automatic pressurization, automatic thickness measurement, fully automatic experimental control. 6-point temperature gradient detection to improve testing accuracy. It can detect the thermal resistance curve under different pressures, uses an optimized mathematical model to measure the thermal conductivity and thermal resistance of materials, and the contact thermal resistance at the interface.
Widely used in colleges and universities, scientific research units, quality inspection departments and manufacturing plants for material analysis and testing.
II. Xiangke DRL-III Thermal Conductivity Tester, Heat Flow Method Main Parameters
Main Parameters | DRL-3 (Standard Type) | DRL-3 (Enhanced Type) | DRL-3P (Vacuum Type) |
1. Sample Size | ≤Φ30mm | ≤Φ30mm | ≤Φ30mm |
2. Sample Thickness | 0.02-20mm | 0.02-20mm | 0.02-20mm |
3. Hot-end Temperature | Room temperature - 99.99℃ | Room temperature - 200℃ | Room temperature - 100℃ |
4. Cold-end Temperature | 0-99.0℃ | 0-99.0℃ | 0-99.0℃ |
5. Thermal Conductivity | 0.1~45 W/m*k | 0.05~45 W/m*k | 0.05~45 W/m*k |
6. Thermal Resistance (m2*K/W) | 0.000005~0.05 | 0.000005~0.05 | 0.000005~0.05 |
7. Testing Accuracy | ≤3% | ≤3% | ≤3% |
7. Pressure Measurement | 0~1000N | 0~1000N | 0~1000N |
8. Displacement Measurement | 0~40mm | 0~40mm | 0~40mm |
9. Pressure Control | Electric | Electric | Electric |
10. Testing Environment | Air | Air | Vacuum |
10. Experimental Methods | a. Thermal resistance test of samples under different pressures. b. Thermal conductivity test of materials. c. Contact thermal resistance test. d. Thermal resistance test of aluminum substrates (composite materials). e. Aging reliability test. | ||
11. Power Supply | Voltage: 220V, Power less than 1KW. | ||
Instrument Selection: The DRL-3 (Enhanced Type) is based on the DRL-3 (Standard Type) with improved hot-end temperature, mainly used for testing materials with slightly higher temperature requirements and slightly lower thermal conductivity; DRL-3P is mainly used for testing materials that are easily oxidized and require a vacuum testing environment.
Previous