Product

Thermal Conductivity Tester


The Xiangtan Xiangke DRL-III series thermal conductivity tester (heat flow method) mainly measures the thermal conductivity, thermal diffusivity, specific heat, heat storage coefficient, and thermal resistance of solids, geotechnical materials, powders, liquids, pastes, coatings, films, and anisotropic materials.

零售价

市场价

库存

Quantity
-
+

库存剩余

隐藏域元素占位

  • 产品描述
    • Commodity name: Thermal Conductivity Tester
    • Model: DRL-III series

    The Xiangtan Xiangke DRL-III series thermal conductivity tester (heat flow method) mainly measures the thermal conductivity, thermal diffusivity, specific heat, heat storage coefficient, and thermal resistance of solids, geotechnical materials, powders, liquids, pastes, coatings, films, and anisotropic materials.

    Xiangtan Xiangke DRL-III Series Thermal Conductivity Tester (Heat Flow Method)

    I. Overview

    This instrument is mainly used to test the thermal resistance of thin thermal conductors, solid electrical insulating materials, thermally conductive resins, silicone rubber and grease, rubber, plastics, beryllium oxide ceramics, alumina ceramics, aluminum-clad copper clad plates and other small materials, as well as the contact thermal resistance at the solid interface and the thermal conductivity of the materials. The test material is in the form of solid flakes. With a frame, powder and paste materials can also be tested.

    Instrument reference standards: MIL-I-49456A (insulating sheets, thermally conductive resins, thermally conductive glass fiber reinforced); GB 5598-2015 (Determination method of thermal conductivity of beryllium oxide ceramics - rod axis method); ASTM D5470-12 (Test standard for thermal performance of thin thermally conductive solid electrical insulating materials), GB/T38712-2020 (Experimental method for thermal conductivity of ultra-thin glass - heat flow method), GB/T29313-2012 Test method for thermal conductivity of electrical insulating materials, etc.

    Instrument features: Automatic pressurization, automatic thickness measurement, fully automatic experimental control. 6-point temperature gradient detection to improve testing accuracy. It can detect the thermal resistance curve under different pressures, uses an optimized mathematical model to measure the thermal conductivity and thermal resistance of materials, and the contact thermal resistance at the interface.

    Widely used in colleges and universities, scientific research units, quality inspection departments and manufacturing plants for material analysis and testing.

    II. DRL-III Series Thermal Conductivity Tester Main Parameters

    Main Parameters

    DRL-3 (Standard Type)

    DRL-3 (Enhanced Type)

      

    1. Sample Size

    ≤Φ30mm

    ≤Φ30mm

      

    2. Sample Thickness

    0.02-20mm

    0.02-20mm

      

    3. Hot Spot Temperature

    Room temperature - 99.99℃

    Room temperature - 200℃

      

    4. Cold Spot Temperature

    0-99.0℃

    0-99.0℃

      

    5. Thermal Conductivity

    0.1~45 W/m*k

    0.05~45 W/m*k

      

    6. Thermal Resistance (m2*K/W)

    0.000005~0.05

    0.000005~0.05

      

    7. Testing Accuracy

    ≤3%

    ≤3%

      

    7. Pressure Measurement

    0~1000N

    0~1000N

      

    8. Displacement Measurement

    0~40mm

    0~40mm

      

    9. Pressure Control

    Electric

    Electric

      

    10. Experimental Methods

    a. Thermal resistance test of samples under different pressures. b. Thermal conductivity test of materials. c. Contact thermal resistance test. d. Thermal resistance test of aluminum substrate (composite materials). e. Aging reliability test.

     

    11. Power Supply

    Voltage: 220V, power less than 1KW.

    Instrument selection: DRL-3 (Enhanced type) is based on DRL-3 (Standard type) to improve the hot spot temperature, mainly used for testing materials with slightly higher temperature requirements and slightly lower thermal conductivity; DRL-3A is mainly used for testing materials with slightly higher temperature requirements; DRL-3B is mainly used for measuring thermal insulation materials.

     

Thermal Conductivity Tester


Model:

DRL-III series

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


The Xiangtan Xiangke DRL-III series thermal conductivity tester (heat flow method) mainly measures the thermal conductivity, thermal diffusivity, specific heat, heat storage coefficient, and thermal resistance of solids, geotechnical materials, powders, liquids, pastes, coatings, films, and anisotropic materials.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

Xiangtan Xiangke DRL-III Series Thermal Conductivity Tester (Heat Flow Method)

I. Overview

This instrument is mainly used to test the thermal resistance of thin thermal conductors, solid electrical insulating materials, thermally conductive resins, silicone rubber and grease, rubber, plastics, beryllium oxide ceramics, alumina ceramics, aluminum-clad copper clad plates and other small materials, as well as the contact thermal resistance at the solid interface and the thermal conductivity of the materials. The test material is in the form of solid flakes. With a frame, powder and paste materials can also be tested.

Instrument reference standards: MIL-I-49456A (insulating sheets, thermally conductive resins, thermally conductive glass fiber reinforced); GB 5598-2015 (Determination method of thermal conductivity of beryllium oxide ceramics - rod axis method); ASTM D5470-12 (Test standard for thermal performance of thin thermally conductive solid electrical insulating materials), GB/T38712-2020 (Experimental method for thermal conductivity of ultra-thin glass - heat flow method), GB/T29313-2012 Test method for thermal conductivity of electrical insulating materials, etc.

Instrument features: Automatic pressurization, automatic thickness measurement, fully automatic experimental control. 6-point temperature gradient detection to improve testing accuracy. It can detect the thermal resistance curve under different pressures, uses an optimized mathematical model to measure the thermal conductivity and thermal resistance of materials, and the contact thermal resistance at the interface.

Widely used in colleges and universities, scientific research units, quality inspection departments and manufacturing plants for material analysis and testing.

II. DRL-III Series Thermal Conductivity Tester Main Parameters

Main Parameters

DRL-3 (Standard Type)

DRL-3 (Enhanced Type)

  

1. Sample Size

≤Φ30mm

≤Φ30mm

  

2. Sample Thickness

0.02-20mm

0.02-20mm

  

3. Hot Spot Temperature

Room temperature - 99.99℃

Room temperature - 200℃

  

4. Cold Spot Temperature

0-99.0℃

0-99.0℃

  

5. Thermal Conductivity

0.1~45 W/m*k

0.05~45 W/m*k

  

6. Thermal Resistance (m2*K/W)

0.000005~0.05

0.000005~0.05

  

7. Testing Accuracy

≤3%

≤3%

  

7. Pressure Measurement

0~1000N

0~1000N

  

8. Displacement Measurement

0~40mm

0~40mm

  

9. Pressure Control

Electric

Electric

  

10. Experimental Methods

a. Thermal resistance test of samples under different pressures. b. Thermal conductivity test of materials. c. Contact thermal resistance test. d. Thermal resistance test of aluminum substrate (composite materials). e. Aging reliability test.

 

11. Power Supply

Voltage: 220V, power less than 1KW.

Instrument selection: DRL-3 (Enhanced type) is based on DRL-3 (Standard type) to improve the hot spot temperature, mainly used for testing materials with slightly higher temperature requirements and slightly lower thermal conductivity; DRL-3A is mainly used for testing materials with slightly higher temperature requirements; DRL-3B is mainly used for measuring thermal insulation materials.

 

Relevant Specifications

Relevant Specifications

Inquire

If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!

Submit