Product

Thermal Conductivity Tester for Polymer Materials, Thermal Resistance Tester


The Xiangke DRL-III polymer material thermal conductivity tester and thermal resistance tester mainly tests the thermal resistance of thin thermal conductors, solid electrical insulating materials, thermally conductive resins, silicone rubber, rubber, beryllium oxide ceramics, aluminum oxide ceramics, aluminum substrates, copper-clad laminates and other small materials, as well as the contact thermal resistance at the solid interface and the thermal conductivity of the materials.

零售价

¥ 48000

市场价

¥ 48000

库存

17

  • Specifications
    • DRL-3 (Standard Type) DRL-3 (Standard Type) Thermal conductivity meter (heat flow method)
    • DRL-3 (Enhanced Type) DRL-3 (Enhanced Type) Thermal conductivity meter (heat flow method)
    • DRL-3P (Vacuum Type) DRL-3P (Vacuum Type) Thermal conductivity meter (heat flow method)

You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
Quantity
-
+

库存剩余

17

隐藏域元素占位

  • 产品描述
    • Commodity name: Thermal Conductivity Tester for Polymer Materials, Thermal Resistance Tester
    • Model: DRL-Ⅲ

    The Xiangke DRL-III polymer material thermal conductivity tester and thermal resistance tester mainly tests the thermal resistance of thin thermal conductors, solid electrical insulating materials, thermally conductive resins, silicone rubber, rubber, beryllium oxide ceramics, aluminum oxide ceramics, aluminum substrates, copper-clad laminates and other small materials, as well as the contact thermal resistance at the solid interface and the thermal conductivity of the materials.

    Xiangke DRL-III Polymer Material Thermal Conductivity Tester, Thermal Resistance Tester

    Xiangtan Xiangke DRL-III Series Thermal Conductivity Tester (Heat Flow Method)

    I. Overview

    This instrument mainly tests the thermal resistance of thin thermal conductors, solid electrical insulating materials, thermally conductive resins, silicone rubber and grease, rubber, plastics, beryllium oxide ceramics, alumina ceramics, aluminum substrates, copper-clad laminates and other small materials, as well as the contact thermal resistance at the solid interface and the thermal conductivity of the materials. The test material is in the form of solid flakes; with a frame added, powder and paste materials can also be tested.

    Instrument reference standards: MIL-I-49456A (insulating sheets, thermally conductive resins, thermally conductive glass fiber reinforced); GB 5598-2015 (Determination method of thermal conductivity of beryllium oxide ceramics, rod axis method); ASTM D5470-12 (Test standard for heat transfer performance of thin thermally conductive solid electrical insulating materials), GB/T38712-2020 (Experimental method for thermal conductivity of ultrathin glass, heat flow method), GB/T29313-2012 Test method for thermal conductivity of electrical insulating materials, etc.

    Instrument features: Automatic pressurization, automatic thickness measurement, fully automatic experimental control. 6-point temperature gradient detection improves testing accuracy. It can detect the thermal resistance curve under different pressures, uses an optimized mathematical model to measure the thermal conductivity and thermal resistance of materials, and the contact thermal resistance at the interface.

    Widely used in colleges and universities, scientific research units, quality inspection departments and manufacturing plants for material analysis and testing.

    II. Xiangke DRL-III Polymer Material Thermal Conductivity Tester, Thermal Resistance Tester Main Parameters

    Main Parameters

    DRL-3 (Standard Type)

    DRL-3 (Enhanced Type)

    DRL-3P(Vacuum type)

    1. Sample Size

    ≤Φ30mm

    ≤Φ30mm

    ≤Φ30mm

    2. Sample Thickness

    0.02-20mm

    0.02-20mm

    0.02-20mm

    3. Hot Spot Temperature

    RT - 99.99℃

    RT - 200℃

    RT - 100℃

    4. Cold Spot Temperature

    0-99.0℃

    0-99.0℃

    0-99.0℃

    5. Thermal Conductivity

    0.1~45 W/m*k

    0.05~45 W/m*k

    0.05~45 W/m*k

    6. Thermal Resistance (m2*K/W)

    0.000005~0.05

    0.000005~0.05

    0.000005~0.05

    7. Testing Accuracy

    ≤3%

    ≤3%

    ≤3%

    7. Pressure Measurement

    0~1000N

    0~1000N

    0~1000N

    8. Displacement Measurement

    0~40mm

    0~40mm

    0~40mm

    9. Pressure Control

    Electric

    Electric

    Electric

    10. Experimental Methods

    a. Thermal resistance test of samples under different pressures. b. Thermal conductivity test of materials. c. Contact thermal resistance test. d. Thermal resistance test of aluminum substrate (composite materials). e. Aging reliability test.

    11.Power Supply

    Voltage: 220V,50HZ, power less than 1KW.

     

     

Thermal Conductivity Tester for Polymer Materials, Thermal Resistance Tester


Model:

DRL-Ⅲ

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


The Xiangke DRL-III polymer material thermal conductivity tester and thermal resistance tester mainly tests the thermal resistance of thin thermal conductors, solid electrical insulating materials, thermally conductive resins, silicone rubber, rubber, beryllium oxide ceramics, aluminum oxide ceramics, aluminum substrates, copper-clad laminates and other small materials, as well as the contact thermal resistance at the solid interface and the thermal conductivity of the materials.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

Xiangke DRL-III Polymer Material Thermal Conductivity Tester, Thermal Resistance Tester

Xiangtan Xiangke DRL-III Series Thermal Conductivity Tester (Heat Flow Method)

I. Overview

This instrument mainly tests the thermal resistance of thin thermal conductors, solid electrical insulating materials, thermally conductive resins, silicone rubber and grease, rubber, plastics, beryllium oxide ceramics, alumina ceramics, aluminum substrates, copper-clad laminates and other small materials, as well as the contact thermal resistance at the solid interface and the thermal conductivity of the materials. The test material is in the form of solid flakes; with a frame added, powder and paste materials can also be tested.

Instrument reference standards: MIL-I-49456A (insulating sheets, thermally conductive resins, thermally conductive glass fiber reinforced); GB 5598-2015 (Determination method of thermal conductivity of beryllium oxide ceramics, rod axis method); ASTM D5470-12 (Test standard for heat transfer performance of thin thermally conductive solid electrical insulating materials), GB/T38712-2020 (Experimental method for thermal conductivity of ultrathin glass, heat flow method), GB/T29313-2012 Test method for thermal conductivity of electrical insulating materials, etc.

Instrument features: Automatic pressurization, automatic thickness measurement, fully automatic experimental control. 6-point temperature gradient detection improves testing accuracy. It can detect the thermal resistance curve under different pressures, uses an optimized mathematical model to measure the thermal conductivity and thermal resistance of materials, and the contact thermal resistance at the interface.

Widely used in colleges and universities, scientific research units, quality inspection departments and manufacturing plants for material analysis and testing.

II. Xiangke DRL-III Polymer Material Thermal Conductivity Tester, Thermal Resistance Tester Main Parameters

Main Parameters

DRL-3 (Standard Type)

DRL-3 (Enhanced Type)

DRL-3P(Vacuum type)

1. Sample Size

≤Φ30mm

≤Φ30mm

≤Φ30mm

2. Sample Thickness

0.02-20mm

0.02-20mm

0.02-20mm

3. Hot Spot Temperature

RT - 99.99℃

RT - 200℃

RT - 100℃

4. Cold Spot Temperature

0-99.0℃

0-99.0℃

0-99.0℃

5. Thermal Conductivity

0.1~45 W/m*k

0.05~45 W/m*k

0.05~45 W/m*k

6. Thermal Resistance (m2*K/W)

0.000005~0.05

0.000005~0.05

0.000005~0.05

7. Testing Accuracy

≤3%

≤3%

≤3%

7. Pressure Measurement

0~1000N

0~1000N

0~1000N

8. Displacement Measurement

0~40mm

0~40mm

0~40mm

9. Pressure Control

Electric

Electric

Electric

10. Experimental Methods

a. Thermal resistance test of samples under different pressures. b. Thermal conductivity test of materials. c. Contact thermal resistance test. d. Thermal resistance test of aluminum substrate (composite materials). e. Aging reliability test.

11.Power Supply

Voltage: 220V,50HZ, power less than 1KW.

 

 

Inquire

If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!

Submit