Product

Thermal Conductivity Meter for Graphite

零售价

市场价


The DR-SM graphite material thermal conductivity meter (graphite thermal conductivity meter) meets the requirements of GB/T8722-2008 "Determination method of thermal conductivity of graphite materials at medium temperature", and is suitable for the determination of thermal conductivity of graphite materials in the range of 100~800℃.

重量

Quantity
-
+

库存剩余

隐藏域元素占位

  • 产品描述
    • Commodity name: Thermal Conductivity Meter for Graphite
    • Model: DR-SM

    The DR-SM graphite material thermal conductivity meter (graphite thermal conductivity meter) meets the requirements of GB/T8722-2008 "Determination method of thermal conductivity of graphite materials at medium temperature", and is suitable for the determination of thermal conductivity of graphite materials in the range of 100~800℃.

    Xiangtan Xiangke DR-SM type graphite material medium temperature thermal conductivity tester ( Graphite thermal conductivity tester ) Introduction:

    This instrument meets the requirements of GB/T8722-2008 "Determination method of thermal conductivity of graphite materials at medium temperature", and is suitable for the determination of thermal conductivity of graphite materials in the range of 100~800℃. Computer-connected automatic testing, data processing and printing of test reports.

    Main technical parameters:

    1. Test temperature range: 100~800℃, using digital instrument temperature measurement, accuracy is better than 0.2 level;

    2. Thermal conductivity test range: 2~80W/M.K;

    3. Sample specifications: Φ16×160mm;

    4. Sample oxidation protection method: Vacuum + atmosphere;

    5. Test accuracy: better than ±5%;

    6. Computer-connected automatic testing, data processing and printing of test reports;

    7. The electric furnace with the highest temperature of 1000℃ or 1300℃ (two specifications are optional);

    8. Power supply: 220V/50Hz; Power ≤4KW;

    9. Connect the computer for automatic testing, data processing, and generate a test report for printing output.

    Xiangtan Xiangke DR-SM type graphite material medium temperature thermal conductivity tester ( Graphite thermal conductivity tester ) Instrument configuration:

    1. One DR-SM test host,

    2. One set of software,

    3. One set of communication interface and data cable,

    4. One set of test thermocouple,

    5. One brand desktop computer (configured according to the contract),

    6. One programmable DC regulated power supply.

    Installation size is about 1500*700*1200mm, placed on the ground, connected to 220V voltage, and an argon gas cylinder (with argon gas) and a matching pressure reducing valve need to be prepared for atmosphere.

Thermal Conductivity Meter for Graphite


Model:

DR-SM

Specifications:

Specifications:

这里是占位文字

Gross weight (KG):


The DR-SM graphite material thermal conductivity meter (graphite thermal conductivity meter) meets the requirements of GB/T8722-2008 "Determination method of thermal conductivity of graphite materials at medium temperature", and is suitable for the determination of thermal conductivity of graphite materials in the range of 100~800℃.


You can send us an email:xtyqyb@163.com

+86 13007446928

Inquire
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Product Details

Xiangtan Xiangke DR-SM type graphite material medium temperature thermal conductivity tester ( Graphite thermal conductivity tester ) Introduction:

This instrument meets the requirements of GB/T8722-2008 "Determination method of thermal conductivity of graphite materials at medium temperature", and is suitable for the determination of thermal conductivity of graphite materials in the range of 100~800℃. Computer-connected automatic testing, data processing and printing of test reports.

Main technical parameters:

1. Test temperature range: 100~800℃, using digital instrument temperature measurement, accuracy is better than 0.2 level;

2. Thermal conductivity test range: 2~80W/M.K;

3. Sample specifications: Φ16×160mm;

4. Sample oxidation protection method: Vacuum + atmosphere;

5. Test accuracy: better than ±5%;

6. Computer-connected automatic testing, data processing and printing of test reports;

7. The electric furnace with the highest temperature of 1000℃ or 1300℃ (two specifications are optional);

8. Power supply: 220V/50Hz; Power ≤4KW;

9. Connect the computer for automatic testing, data processing, and generate a test report for printing output.

Xiangtan Xiangke DR-SM type graphite material medium temperature thermal conductivity tester ( Graphite thermal conductivity tester ) Instrument configuration:

1. One DR-SM test host,

2. One set of software,

3. One set of communication interface and data cable,

4. One set of test thermocouple,

5. One brand desktop computer (configured according to the contract),

6. One programmable DC regulated power supply.

Installation size is about 1500*700*1200mm, placed on the ground, connected to 220V voltage, and an argon gas cylinder (with argon gas) and a matching pressure reducing valve need to be prepared for atmosphere.

Relevant Specifications

Relevant Specifications

Inquire

If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!

Submit