- Commodity name: Ceramic Tile Frost Resistance Tester, Ceramic Testing Instrument
- Model: Hunan Science and Technology CLD
Xiangke CLD ceramic tile frost resistance tester, ceramic testing instrument meets GB/3810.12-2016, is a device for measuring the frost resistance of ceramic tiles.
Xiangke CLD Ceramic Tile Freeze-thaw Resistance Tester, Ceramic Testing Instrument
The CLD ceramic testing instrument is used to measure the freeze-thaw resistance of ceramic tiles. The instrument conforms to the requirements of GB/3810.12-2016 and ISO10545-12:1995 for the freeze-thaw resistance test of ceramic tiles.
Xiangke CLD Ceramic Tile Freeze-thaw Resistance Tester, Ceramic Testing Instrument Main Technical Parameters:
1. Test area operating temperature adjustment range: -15℃—+15℃;
2. Test area: 600×600×300 (mm);
3. Temperature control accuracy: ±1℃;
5. Test method: Automatically complete the test cycle according to the set number of tests.
6. Power supply: 220V ±10% 2.5 kw;
Working conditions:1. Ambient temperature: 0~40℃;
2. Power supply: 220V, 50 HZ;
3. Equipped with water inlet and outlet pipes;Instrument components:
The instrument consists of three parts: a freezing test chamber, a water inlet and outlet system, and a temperature control and automatic control system.
The working principle of this instrument is designed and implemented according to the requirements of GB/3810.12-2016 national standard.
According to the test requirements, set the electronic counter to the required number of test cycles (100 times). Place the samples in the test area and close the cover. Cool the test area to -5℃ and maintain for 15 minutes. Open the water pump to spray water on the samples to raise the test temperature to +5℃ and maintain for 15 minutes. The counter counts once. According to the test requirements, set the electronic counter to the required number of test cycles (100 times). Automatically perform the above cycle test. An alarm will be given after the test is completed.
Configuration: Includes one CLD host and one stainless steel sample rack.
Ceramic Tile Frost Resistance Tester, Ceramic Testing Instrument
Model:
Hunan Science and Technology CLD
Specifications:
Specifications:
这里是占位文字
Gross weight (KG):
Xiangke CLD ceramic tile frost resistance tester, ceramic testing instrument meets GB/3810.12-2016, is a device for measuring the frost resistance of ceramic tiles.
Category:
You can send us an email:xtyqyb@163.com
InquireProduct Details
Xiangke CLD Ceramic Tile Freeze-thaw Resistance Tester, Ceramic Testing Instrument
The CLD ceramic testing instrument is used to measure the freeze-thaw resistance of ceramic tiles. The instrument conforms to the requirements of GB/3810.12-2016 and ISO10545-12:1995 for the freeze-thaw resistance test of ceramic tiles.
Xiangke CLD Ceramic Tile Freeze-thaw Resistance Tester, Ceramic Testing Instrument Main Technical Parameters:
1. Test area operating temperature adjustment range: -15℃—+15℃;
2. Test area: 600×600×300 (mm);
3. Temperature control accuracy: ±1℃;
5. Test method: Automatically complete the test cycle according to the set number of tests.
6. Power supply: 220V ±10% 2.5 kw;
Working conditions:
1. Ambient temperature: 0~40℃;
2. Power supply: 220V, 50 HZ;
3. Equipped with water inlet and outlet pipes;
Instrument components:
The instrument consists of three parts: a freezing test chamber, a water inlet and outlet system, and a temperature control and automatic control system.
The working principle of this instrument is designed and implemented according to the requirements of GB/3810.12-2016 national standard.
According to the test requirements, set the electronic counter to the required number of test cycles (100 times). Place the samples in the test area and close the cover. Cool the test area to -5℃ and maintain for 15 minutes. Open the water pump to spray water on the samples to raise the test temperature to +5℃ and maintain for 15 minutes. The counter counts once. According to the test requirements, set the electronic counter to the required number of test cycles (100 times). Automatically perform the above cycle test. An alarm will be given after the test is completed.
Configuration: Includes one CLD host and one stainless steel sample rack.