Flexural Modulus Tester
零售价
市场价
重量
库存剩余
隐藏域元素占位
- 产品描述
-
- Commodity name: Flexural Modulus Tester
- Model: Hunan Science and Technology GTM
The Xiangke GTM bending method elastic modulus tester meets the GB/10700-2006 standard "Fine ceramic elastic modulus test method - bending method", and is suitable for the determination of elastic modulus of engineering ceramics, fine ceramics, and functional ceramics at room temperature. 1. Maximum load: 0~10000N; 2. Force measurement accuracy: Relative error ≤ ±0.15%
Xiangke GTM Flexural Modulus Testing Machine
Xiangke GTM Flexural Modulus Testing Machine Complies with GB/10700-2006 "Test Method for Elastic Modulus of Fine Ceramics - Flexural Method", suitable for determining the elastic modulus of engineering ceramics, fine ceramics, and functional ceramics at room temperature.
This instrument uses a three-point bending loading method to measure the elastic modulus of ceramics. It consists of an electric loading system, a deformation measurement system, a pressure measurement system, and a computer control system. The electric loading system consists of a variable frequency speed regulator, a precision reducer, and a lifting device; the deformation measurement system uses a high-precision displacement sensor to measure micro-strain; the pressure measurement system uses a high-precision pressure sensor and a digital pressure gauge for measurement; the three control systems are controlled by a computer to achieve fully automatic testing.
Main Technical Parameters
1. Load range: 0~10000N or 0~50000N (other specifications can be customized according to user requirements);
2. Force measurement accuracy: Relative error ≤ ±0.15%;
3. Deformation measurement range: ±5mm;
4. Deformation accuracy: Relative error ≤ ±0.5%;
5. Loading deformation rate: 0~1mm/min, adjustable;6. Sample size: ≤120*100mm (conventional, according to GB/10700-2006);
Or: Diameter 50mm, length 50mm (according to YS/T63.13-2006 standard);
Or: 820*100mm (according to GB/T23266-2009 standard);
(Other specifications can be customized according to user requirements)
7. Voltage: 380V;
Configuration: Includes one GTM-II testing host, one software, one set of testing fixtures, and one desktop computer (as per contract configuration).
Factory direct supply, quality assurance!
Flexural Modulus Tester
Model:
Hunan Science and Technology GTM
Specifications:
Specifications:
这里是占位文字
Gross weight (KG):
The Xiangke GTM bending method elastic modulus tester meets the GB/10700-2006 standard "Fine ceramic elastic modulus test method - bending method", and is suitable for the determination of elastic modulus of engineering ceramics, fine ceramics, and functional ceramics at room temperature. 1. Maximum load: 0~10000N; 2. Force measurement accuracy: Relative error ≤ ±0.15%
Category:
You can send us an email:xtyqyb@163.com
InquireProduct Details
Xiangke GTM Flexural Modulus Testing Machine
Xiangke GTM Flexural Modulus Testing Machine Complies with GB/10700-2006 "Test Method for Elastic Modulus of Fine Ceramics - Flexural Method", suitable for determining the elastic modulus of engineering ceramics, fine ceramics, and functional ceramics at room temperature.
This instrument uses a three-point bending loading method to measure the elastic modulus of ceramics. It consists of an electric loading system, a deformation measurement system, a pressure measurement system, and a computer control system. The electric loading system consists of a variable frequency speed regulator, a precision reducer, and a lifting device; the deformation measurement system uses a high-precision displacement sensor to measure micro-strain; the pressure measurement system uses a high-precision pressure sensor and a digital pressure gauge for measurement; the three control systems are controlled by a computer to achieve fully automatic testing.
Main Technical Parameters
1. Load range: 0~10000N or 0~50000N (other specifications can be customized according to user requirements);
2. Force measurement accuracy: Relative error ≤ ±0.15%;
3. Deformation measurement range: ±5mm;
4. Deformation accuracy: Relative error ≤ ±0.5%;
5. Loading deformation rate: 0~1mm/min, adjustable;
6. Sample size: ≤120*100mm (conventional, according to GB/10700-2006);
Or: Diameter 50mm, length 50mm (according to YS/T63.13-2006 standard);
Or: 820*100mm (according to GB/T23266-2009 standard);
(Other specifications can be customized according to user requirements)
7. Voltage: 380V;
Configuration: Includes one GTM-II testing host, one software, one set of testing fixtures, and one desktop computer (as per contract configuration).
Factory direct supply, quality assurance!
Relevant Specifications
Relevant Specifications
Recommend
Recommend
Inquire
If you are interested in our products, please leave your email and we will contact you as soon as possible. Thank you!